Virtual Reality Hemifield Measurements for Corrective Surgery Eligibility in Ptosis Patients: A Pilot Clinical Trial

Margarita Labkovich, Andrew J. Warburton, Stephanie Ying, Aly A. Valliani, Nicholas Kissel, Randal A. Serafini, Raj Mathew, Megan Paul, S. Malin Hovstadius, Vicente N. Navarro, Aashay Patel, Harsha Reddy, James G. Chelnis

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Purpose: We developed an accelerated virtual reality (VR) suprathreshold hemifield perimetry algorithm, the median cut hemifield test (MCHT). This study examines the ability of the MCHT to determine ptosis severity and its reversibility with an artificial improvement by eyelid taping on an HTC Vive Pro Eye VR headset and the Humphrey visual field analyzer (HVFA) to assess the capabilities of emerging technologies in evaluating ptosis. Methods: In a single visit, the MCHT was administered along with the HVFA 30-2 on ptotic untaped and taped eyelids in a randomized order. The primary end points were a superior field visibility comparison with severity of VF loss and VF improvement after taping for MCHT and HVFA. Secondary end points included evaluating patients’ Likertscaled survey responses on the comfort, speed, and overall experience with both testing modalities. Results: VR’s MCHT superior field degrees visible correlated well for severe category margin to reflex distance (r = 0.78) compared with HVFA’s (r =−0.21). The MCHT also demonstrated noninferiority (83.3% agreement; P = 1) against HVFA for detection of 30% or more superior visual field improvement after taping, warranting a corrective surgical intervention. In comparing hemi-VF in untaped eyes, both tests demonstrated relative obstruction to the field when comparing normal controls to severe ptosis (HVFA P < 0.05; MCHT P < 0.001), which proved sufficient to demonstrate percent improvement with taping. The secondary end point of patient satisfaction favored VR vision testing presentation mode in terms of comfort (P < 0.01), speed (P < 0.001), and overall experience (P < 0.01). Conclusions: This pilot trial supports the use of MCHT for the quantitative measurement of visual field loss owing to ptosis and the reversibility of ptosis that is tested when conducting a presurgical evaluation. We believe the adoption of MCHT testing in oculoplastic clinics could decrease patient burden and accelerate time to corrective treatment. Translational Relevance: In this study, we look at vision field outputs in patients with ptosis to evaluate its severity and improvement with eyelid taping on a low-profile VRbased technology and compare it with HVFA. Our results demonstrate that alternative, portable technologies such as VR can be used to grade the degree of ptosis and determine whether ptosis surgery could provide a significant superior visual field improvement of 30% or more, all while ensuring a more comfortable experience and faster testing time.

Original languageEnglish
Article number35
JournalTranslational Vision Science and Technology
Volume11
Issue number10
DOIs
StatePublished - Oct 2022

Keywords

  • hemifield
  • humphrey visual field analyzer
  • perimetry
  • ptosis
  • virtual reality

Fingerprint

Dive into the research topics of 'Virtual Reality Hemifield Measurements for Corrective Surgery Eligibility in Ptosis Patients: A Pilot Clinical Trial'. Together they form a unique fingerprint.

Cite this