Venous-Left Atrial Extracorporeal Membrane Oxygenation Configuration Use in Right Ventricular Failure and Tricuspid Ring

Harish Ravipati, Mouhamed Amr Sabouni, Tejasri Kodavaluru, Hassan Alkhawam, Mustafa I. Ahmed

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

Mechanical circulatory support devices are used to support the heart in cardiogenic shock. We present a case of demonstrating the feasible use of left ventricular assistive device with reverse configuration to support severe right ventricular failure in a patient with recent tricuspid annuloplasty ring.

Original languageEnglish
Pages (from-to)1263-1266
Number of pages4
JournalJACC: Case Reports
Volume4
Issue number19
DOIs
StatePublished - 5 Oct 2022
Externally publishedYes

Keywords

  • cardiac assist devices
  • right ventricle
  • tricuspid valve

Fingerprint

Dive into the research topics of 'Venous-Left Atrial Extracorporeal Membrane Oxygenation Configuration Use in Right Ventricular Failure and Tricuspid Ring'. Together they form a unique fingerprint.

Cite this