Vascular response to percutaneous coronary intervention with biodegradable-polymer vs. new-generation durable-polymer drug-eluting stents: A meta-analysis of optical coherence tomography imaging trials

  • Salvatore Cassese
  • , Erion Xhepa
  • , Gjin Ndrepepa
  • , Sebastian Kufner
  • , Roisin Colleran
  • , Daniele Giacoppo
  • , Tobias Koppara
  • , Nader Mankerious
  • , Robert A. Byrne
  • , Karl Ludwig Laugwitz
  • , Heribert Schunkert
  • , Massimiliano Fusaro
  • , Adnan Kastrati
  • , Michael Joner

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

Aims Whether biodegradable-polymer drug-eluting stents (BP-DES) induce a vascular response at follow-up more favourable than that of new-generation durable-polymer drug-eluting stents (DP-DES) remains controversial. We sought to evaluate the vascular response to percutaneous coronary intervention (PCI) with BP-DES vs. new-generation DP-DES as assessed by optical coherence tomography (OCT) imaging at follow-up. Methods and results We undertook a meta-analysis of aggregate data by searching electronic scientific databases for investigations of PCI-patients receiving BP-DES vs. new-generation DP-DES and OCT imaging at follow-up. The primary outcome was neointima hyperplasia (NIH) thickness. The co-primary outcome was the incidence of lesions with uncovered struts. The main secondary outcome was the incidence of lesions with malapposed struts. Among 10 trials, a total of 544 PCI-patients were assigned to BP-DES (n = 282) or new-generation DP-DES (n = 262). Of these, 447 participants with 480 treated lesions had analysable OCT imaging at a weighted median follow-up of 7 months. Lesions treated with BP-DES vs. new-generation DP-DES showed comparable NIH thickness [weighted mean difference 95% confidence intervals (CI)= 11.37 (29.25, 6.52); P = 0.21]. However, thick-struts (>100 μm) BP-DES showed less NIH thickness as compared to new-generation DP-DES [20.39 (33.83, 6.95); P = 0.003]. BP-DES vs. new-generation DP-DES showed a higher risk for uncovered struts [odds ratio 95% CI = 3.50 (1.69-7.26); P = 0.0008] and a trend towards higher risk for malapposed struts [2.01 (0.98-4.12); P = 0.06]. Conclusion In PCI-patients with available OCT imaging at follow-up, BP-DES with thicker backbones delay vascular response as compared with new-generation DP-DES. All rights reserved.

Original languageEnglish
Pages (from-to)1294-1301
Number of pages8
JournalEuropean Heart Journal Cardiovascular Imaging
Volume19
Issue number11
DOIs
StatePublished - 1 Nov 2018
Externally publishedYes

Keywords

  • biodegradable polymer
  • drug-eluting stent
  • durable polymer
  • meta-analysis
  • optical coherence tomography
  • percutaneous coronary intervention