TY - JOUR
T1 - Validation study of the accuracy of echocardiographic measurements of systemic blood flow volume in newborn infants
AU - Ficial, Benjamim
AU - Finnemore, Anna E.
AU - Cox, David J.
AU - Broadhouse, Kathryn M.
AU - Price, Anthony N.
AU - Durighel, Giuliana
AU - Ekitzidou, Georgia
AU - Hajnal, Joseph V.
AU - Edwards, A. David
AU - Groves, Alan M.
PY - 2013/12
Y1 - 2013/12
N2 - Background The echocardiographic assessment of circulatory function in sick newborn infants has the potential to improve patient care. However, measurements are prone to error and have not been sufficiently validated. Phase-contrast magnetic resonance imaging (MRI) provides highly validated measures of blood flow and has recently been applied to the newborn population. The aim of this study was to validate measures of left ventricular output and superior vena caval flow volume in newborn infants. Methods Echocardiographic and MRI assessments were performed within 1 working day of each other in a cohort of newborn infants. Results Examinations were performed in 49 infants with a median corrected gestational age at scan of 34.43 weeks (range, 27.43-40 weeks) and a median weight at scan of 1,880 g (range, 660-3,760 g). Echocardiographic assessment of left ventricular output showed a strong correlation with MRI assessment (R2 = 0.83; mean bias, -9.6 mL/kg/min; limits of agreement, -79.6 to +60.0 mL/kg/min; repeatability index, 28.2%). Echocardiographic assessment of superior vena caval flow showed a poor correlation with MRI assessment (R2 = 0.22; mean bias, -13.7 mL/kg/min; limits of agreement, -89.1 to +61.7 mL/kg/min; repeatability index, 68.0%). Calculating superior vena caval flow volume from an axial area measurement and applying a 50% reduction to stroke distance to compensate for overestimation gave a slightly improved correlation with MRI (R2 = 0.29; mean bias, 2.6 mL/kg/min; limits of agreement, -53.4 to +58.6 mL/kg/min; repeatability index, 54.5%). Conclusions Echocardiographic assessment of left ventricular output appears relatively robust in newborn infant. Echocardiographic assessment of superior vena caval flow is of limited accuracy in this population, casting doubt on the utility of the measurement for diagnostic decision making.
AB - Background The echocardiographic assessment of circulatory function in sick newborn infants has the potential to improve patient care. However, measurements are prone to error and have not been sufficiently validated. Phase-contrast magnetic resonance imaging (MRI) provides highly validated measures of blood flow and has recently been applied to the newborn population. The aim of this study was to validate measures of left ventricular output and superior vena caval flow volume in newborn infants. Methods Echocardiographic and MRI assessments were performed within 1 working day of each other in a cohort of newborn infants. Results Examinations were performed in 49 infants with a median corrected gestational age at scan of 34.43 weeks (range, 27.43-40 weeks) and a median weight at scan of 1,880 g (range, 660-3,760 g). Echocardiographic assessment of left ventricular output showed a strong correlation with MRI assessment (R2 = 0.83; mean bias, -9.6 mL/kg/min; limits of agreement, -79.6 to +60.0 mL/kg/min; repeatability index, 28.2%). Echocardiographic assessment of superior vena caval flow showed a poor correlation with MRI assessment (R2 = 0.22; mean bias, -13.7 mL/kg/min; limits of agreement, -89.1 to +61.7 mL/kg/min; repeatability index, 68.0%). Calculating superior vena caval flow volume from an axial area measurement and applying a 50% reduction to stroke distance to compensate for overestimation gave a slightly improved correlation with MRI (R2 = 0.29; mean bias, 2.6 mL/kg/min; limits of agreement, -53.4 to +58.6 mL/kg/min; repeatability index, 54.5%). Conclusions Echocardiographic assessment of left ventricular output appears relatively robust in newborn infant. Echocardiographic assessment of superior vena caval flow is of limited accuracy in this population, casting doubt on the utility of the measurement for diagnostic decision making.
KW - Echocardiography
KW - Phase-contrast MRI
KW - Preterm infants
UR - http://www.scopus.com/inward/record.url?scp=84888437997&partnerID=8YFLogxK
U2 - 10.1016/j.echo.2013.08.019
DO - 10.1016/j.echo.2013.08.019
M3 - Article
C2 - 24075229
AN - SCOPUS:84888437997
SN - 0894-7317
VL - 26
SP - 1365
EP - 1371
JO - Journal of the American Society of Echocardiography
JF - Journal of the American Society of Echocardiography
IS - 12
ER -