TY - JOUR
T1 - Two-Year Outcomes With a Next-Generation Left Atrial Appendage Device
T2 - Final Results of the PINNACLE FLX Trial
AU - PINNACLE FLX investigators [Link]
AU - Doshi, Shephal K.
AU - Kar, Saibal
AU - Sadhu, Ashish
AU - Horton, Rodney
AU - Osorio, Jose
AU - Ellis, Christopher
AU - Stone, James
AU - Shah, Manish
AU - Dukkipati, Srinivas R.
AU - Adler, Stuart
AU - Nair, Devi G.
AU - Kim, Jamie
AU - Wazni, Oussama
AU - Price, Matthew J.
AU - Holmes, David R.
AU - Shipley, Robert
AU - Christen, Thomas
AU - Allocco, Dominic J.
AU - Reddy, Vivek Y.
PY - 2023/2/21
Y1 - 2023/2/21
N2 - Background The PINNACLE FLX (Protection Against Embolism for Non-valvular AF [Atrial Fibrillation] Patients: Investigational Device Evaluation of the Watchman FLX LAA [Left Atrial Appendage] Closure Technology) trial evaluated the safety and efficacy of a next-generation left atrial appendage closure device (WATCHMAN FLX; Boston Scientific, Marlborough, MA). At 1 year, the study met the primary end points of safety and anatomical efficacy/appendage closure. This final report of the PINNACLE FLX trial includes the prespecified secondary end point of ischemic stroke or systemic embolism at 2 years, also making it the first report of 2-year outcomes with this next-generation left atrial appendage closure device. Methods and Results Patients with nonvalvular atrial fibrillation with CHA2DS2-VASc score ≥2 (men) or ≥3 (women), with an appropriate rationale for left atrial appendage closure, were enrolled to receive the left atrial appendage closure device at 29 US centers. Adverse events were assessed by an independent clinical events committee, and imaging was assessed by independent core laboratories. Among 395 implanted patients (36% women; mean age, 74 years; CHA2DS2-VASc, 4.2±1.5), the secondary efficacy end point of 2-year ischemic stroke or systemic embolism was met, with an absolute rate of 3.4% (annualized rate, 1.7%) and an upper 1-sided 95% confidence bound of 5.3%, which was superior to the 8.7% performance goal. Two-year rates of adverse events were as follows: 9.3% all-cause mortality, 5.5% cardiovascular death, 3.4% all stroke, and 10.1% major bleeding (Bleeding Academic Research Consortium 3 or 5). There were no additional systemic embolisms, device embolizations, pericardial effusions, or symptomatic device-related thrombi after 1 year. Conclusions The secondary end point of 2-year stroke or systemic embolism was met at 3.4%. In these final results of the PINNACLE FLX trial, the next-generation WATCHMAN FLX device demonstrated favorable safety and efficacy outcomes.
AB - Background The PINNACLE FLX (Protection Against Embolism for Non-valvular AF [Atrial Fibrillation] Patients: Investigational Device Evaluation of the Watchman FLX LAA [Left Atrial Appendage] Closure Technology) trial evaluated the safety and efficacy of a next-generation left atrial appendage closure device (WATCHMAN FLX; Boston Scientific, Marlborough, MA). At 1 year, the study met the primary end points of safety and anatomical efficacy/appendage closure. This final report of the PINNACLE FLX trial includes the prespecified secondary end point of ischemic stroke or systemic embolism at 2 years, also making it the first report of 2-year outcomes with this next-generation left atrial appendage closure device. Methods and Results Patients with nonvalvular atrial fibrillation with CHA2DS2-VASc score ≥2 (men) or ≥3 (women), with an appropriate rationale for left atrial appendage closure, were enrolled to receive the left atrial appendage closure device at 29 US centers. Adverse events were assessed by an independent clinical events committee, and imaging was assessed by independent core laboratories. Among 395 implanted patients (36% women; mean age, 74 years; CHA2DS2-VASc, 4.2±1.5), the secondary efficacy end point of 2-year ischemic stroke or systemic embolism was met, with an absolute rate of 3.4% (annualized rate, 1.7%) and an upper 1-sided 95% confidence bound of 5.3%, which was superior to the 8.7% performance goal. Two-year rates of adverse events were as follows: 9.3% all-cause mortality, 5.5% cardiovascular death, 3.4% all stroke, and 10.1% major bleeding (Bleeding Academic Research Consortium 3 or 5). There were no additional systemic embolisms, device embolizations, pericardial effusions, or symptomatic device-related thrombi after 1 year. Conclusions The secondary end point of 2-year stroke or systemic embolism was met at 3.4%. In these final results of the PINNACLE FLX trial, the next-generation WATCHMAN FLX device demonstrated favorable safety and efficacy outcomes.
KW - WATCHMAN FLX
KW - atrial fibrillation
KW - left atrial appendage closure
UR - http://www.scopus.com/inward/record.url?scp=85148479610&partnerID=8YFLogxK
U2 - 10.1161/JAHA.122.026295
DO - 10.1161/JAHA.122.026295
M3 - Article
C2 - 36789852
AN - SCOPUS:85148479610
SN - 2047-9980
VL - 12
SP - e026295
JO - Journal of the American Heart Association
JF - Journal of the American Heart Association
IS - 4