Transcatheter Closure of a Very Large Patent Ductus Arteriosus in a Pregnant Woman at 22 Weeks of Gestation

Joshua P. Kanter, William E. Hellenbrand, Robert H. Pass

Research output: Contribution to journalArticlepeer-review

4 Scopus citations

Abstract

Successful transcatheter closure of a large PDA in a pregnant patient is reported using the Amplatzer ductal occluder device. This procedure was safe and uncomplicated, obviating the need for surgery in this high risk patient.

Original languageEnglish
Pages (from-to)140-143
Number of pages4
JournalCatheterization and Cardiovascular Interventions
Volume61
Issue number1
DOIs
StatePublished - Jan 2004
Externally publishedYes

Keywords

  • Gestation
  • PDA
  • Transcatheter closure