TY - JOUR
T1 - Transcatheter Aortic Valve Implantation by Valve Type in Women with Small Annuli
T2 - Results from the SMART Randomized Clinical Trial
AU - Tchétché, Didier
AU - Mehran, Roxana
AU - Blackman, Daniel J.
AU - Khalil, Ramzi F.
AU - Möllmann, Helge
AU - Abdel-Wahab, Mohamed
AU - Ben Ali, Walid
AU - Mahoney, Paul D.
AU - Ruge, Hendrik
AU - Bleiziffer, Sabine
AU - Lin, Lang
AU - Szerlip, Molly
AU - Grubb, Kendra J.
AU - Byku, Isida
AU - Guerrero, Mayra
AU - Gillam, Linda D.
AU - Petronio, Anna Sonia
AU - Attizzani, Guilherme F.
AU - Batchelor, Wayne B.
AU - Gada, Hemal
AU - Rogers, Toby
AU - Rovin, Joshua D.
AU - Whisenant, Brian
AU - Benton, Stewart
AU - Gardner, Blake
AU - Padang, Ratnasari
AU - Althouse, Andrew D.
AU - Herrmann, Howard C.
N1 - Publisher Copyright:
© 2024 American Medical Association. All rights reserved.
PY - 2024/12/11
Y1 - 2024/12/11
N2 - Importance: Historically, women with aortic stenosis have experienced worse outcomes and inadequate recognition compared to men, being both underdiagnosed and undertreated, while also facing underrepresentation in clinical trials. Objective: To determine whether women with small aortic annuli undergoing transcatheter aortic valve replacement have better clinical and hemodynamic outcomes with a self-expanding valve (SEV) or balloon-expandable valve (BEV). Design, Setting, Participants: The Small Annuli Randomized to Evolut or SAPIEN Trial (SMART) was a large-scale randomized clinical trial focusing on patients with small aortic annuli undergoing transcatheter aortic valve replacement, randomized to receive SEVs or BEVs and included 716 patients treated at 83 centers in Canada, Europe, Israel, and the US from April 2021 to October 2022. This prespecified secondary analysis reports clinical and hemodynamic findings for all 621 women enrolled in SMART. Data for this report were analyzed from February to April 2024. Interventions: Transcatheter aortic valve replacement with an SEV or a BEV. Main Outcomes and Measures: The composite coprimary clinical end point comprised death, disabling stroke, or heart failure-related rehospitalization. The coprimary valve function end point was the incidence of bioprosthetic valve dysfunction, both assessed through 12 months. Secondary end points included the incidence of moderate or severe prosthesis-patient mismatch. Results: A total of 621 women (mean [SD] age, 80.2 [6.2] years; 312 randomized to the SEV group and 309 to the BEV group) were included in the present analysis. At 12 months, there were no significant differences in the coprimary clinical end point between the SEV and BEV groups (9.4% vs 11.8%, absolute risk difference-2.3%; 95% CI-7.2 to 2.5, P =.35). However, SEV implantation was associated with less bioprosthetic valve dysfunction (8.4% vs 41.8%; absolute risk difference,-33.4%; 95% CI,-40.4 to-26.4; P <.001). SEV implantation resulted in lower aortic valve gradients and larger effective orifice areas at 30 days and 12 months and less mild or greater aortic regurgitation at 12 months compared to BEV implantation. Prosthesis-patient mismatch was significantly lower with SEVs, regardless of the definition used and adjustment for body mass index. Use of SEVs was associated with better quality of life outcomes as assessed by the Valve Academic Research Consortium-3 ordinal quality of life measure. Conclusions and Relevance: Among women with severe symptomatic aortic stenosis and small aortic annuli undergoing transcatheter aortic valve replacement, the use of SEVs, compared to BEVs, resulted in similar clinical outcomes and a markedly reduced incidence of bioprosthetic valve dysfunction through 12 months, including a lower risk of prosthesis-patient mismatch and better 12-month quality of life. Trial Registration: ClinicalTrials.gov Identifier: NCT04722250.
AB - Importance: Historically, women with aortic stenosis have experienced worse outcomes and inadequate recognition compared to men, being both underdiagnosed and undertreated, while also facing underrepresentation in clinical trials. Objective: To determine whether women with small aortic annuli undergoing transcatheter aortic valve replacement have better clinical and hemodynamic outcomes with a self-expanding valve (SEV) or balloon-expandable valve (BEV). Design, Setting, Participants: The Small Annuli Randomized to Evolut or SAPIEN Trial (SMART) was a large-scale randomized clinical trial focusing on patients with small aortic annuli undergoing transcatheter aortic valve replacement, randomized to receive SEVs or BEVs and included 716 patients treated at 83 centers in Canada, Europe, Israel, and the US from April 2021 to October 2022. This prespecified secondary analysis reports clinical and hemodynamic findings for all 621 women enrolled in SMART. Data for this report were analyzed from February to April 2024. Interventions: Transcatheter aortic valve replacement with an SEV or a BEV. Main Outcomes and Measures: The composite coprimary clinical end point comprised death, disabling stroke, or heart failure-related rehospitalization. The coprimary valve function end point was the incidence of bioprosthetic valve dysfunction, both assessed through 12 months. Secondary end points included the incidence of moderate or severe prosthesis-patient mismatch. Results: A total of 621 women (mean [SD] age, 80.2 [6.2] years; 312 randomized to the SEV group and 309 to the BEV group) were included in the present analysis. At 12 months, there were no significant differences in the coprimary clinical end point between the SEV and BEV groups (9.4% vs 11.8%, absolute risk difference-2.3%; 95% CI-7.2 to 2.5, P =.35). However, SEV implantation was associated with less bioprosthetic valve dysfunction (8.4% vs 41.8%; absolute risk difference,-33.4%; 95% CI,-40.4 to-26.4; P <.001). SEV implantation resulted in lower aortic valve gradients and larger effective orifice areas at 30 days and 12 months and less mild or greater aortic regurgitation at 12 months compared to BEV implantation. Prosthesis-patient mismatch was significantly lower with SEVs, regardless of the definition used and adjustment for body mass index. Use of SEVs was associated with better quality of life outcomes as assessed by the Valve Academic Research Consortium-3 ordinal quality of life measure. Conclusions and Relevance: Among women with severe symptomatic aortic stenosis and small aortic annuli undergoing transcatheter aortic valve replacement, the use of SEVs, compared to BEVs, resulted in similar clinical outcomes and a markedly reduced incidence of bioprosthetic valve dysfunction through 12 months, including a lower risk of prosthesis-patient mismatch and better 12-month quality of life. Trial Registration: ClinicalTrials.gov Identifier: NCT04722250.
UR - https://www.scopus.com/pages/publications/85209386432
U2 - 10.1001/jamacardio.2024.3241
DO - 10.1001/jamacardio.2024.3241
M3 - Article
C2 - 39382856
AN - SCOPUS:85209386432
SN - 2380-6583
VL - 9
JO - JAMA Cardiology
JF - JAMA Cardiology
IS - 12
M1 - e002373
ER -