Tissue proliferation within and surrounding Palmaz-Schatz stents is dependent on the aggressiveness of stent implantation technique

Rainer Hoffmann, Gary S. Mintz, Roxana Mehran, Kenneth M. Kent, Augusto D. Pichard, Lowell F. Satler, Martin B. Leon

Research output: Contribution to journalArticlepeer-review

110 Scopus citations

Abstract

In-stent restenosis is entirely due to intimal hyperplasia. Histologic studies have indicated that intimal hyperplasia is related to the arterial injury induced during stent implantation. We used intravascular ultrasound (IVUS) imaging to study whether tissue proliferation inside and surrounding stents is related to the aggressiveness of the implantation technique. After intervention and follow-up (mean 5.6 ± 3.7 months), serial IVUS imaging was performed in 102 native artery stented stenoses in 91 patients. Measurements at 5 predetermined segments within each stented lesion included external elastic membrane, stent, and lumen cross-sectional areas (CSAs). Calculations included mean plaque CSA growth outside of the stent (external elastic membrane-stent) and mean neointimal hyperplasia CSA and thickness within the stent (stent-lumen). Stenoses were categorized depending on the aggressiveness of stent placement (group 1, adjunct percutaneous transluminal coronary angioplasty pressure <16 atm and/or balloon/artery ratio < 1.1; group 2, adjunct percutaneous transluminal coronary angioplasty pressure ≥16 atm and balloon/artery ratio ≥1.1). An aggressiveness score was calculated as balloon/artery ratio · inflation pressure. Mean intimal hyperplasia CSA (2.9 ± 1.5 vs 2.2 ± 1.6 mm2, p = 0.028), mean intimal hyperplasia thickness (0.34 ± 0.19 vs 0.25 ± 0.19 mm, p = 0.012), and mean peristent tissue growth CSA (2.5 ± 1.0 vs 1.1 ± 1.4 mm2, p = 0.003) were significantly greater in group 2 stenoses. In addition, intimal hyperplasia CSA and thickness correlated significantly with balloon/artery ratio · inflation pressures: r = 0.305, p = 0.002 and r = 0.329, p = 0.0007, respectively, as did peristent tissue proliferation CSA (r = 0.466, p = 0.001). Tissue proliferation inside and surrounding stents may be related to aggressiveness of the stent implantation technique.

Original languageEnglish
Pages (from-to)1170-1174
Number of pages5
JournalAmerican Journal of Cardiology
Volume83
Issue number8
DOIs
StatePublished - 15 Apr 1999
Externally publishedYes

Fingerprint

Dive into the research topics of 'Tissue proliferation within and surrounding Palmaz-Schatz stents is dependent on the aggressiveness of stent implantation technique'. Together they form a unique fingerprint.

Cite this