Skip to main navigation Skip to search Skip to main content

176Lu effect on the minimum detectable activity limits for a dual head, LSO: Ce based, PET system

  • Nikos Efthimiou
  • , George Loudos
  • , Nicolas A. Karakatsanis
  • , George Panayotakis

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

Novel molecular imaging applications increasingly involve studies were very low amount of radiotracer is injected into the subject. This is a challenging problem in terms of image quality, especially when intrinsic radioactivity from the detector is considered. LSO crystals contain 176Lu, which spontaneously emits b- particles and γ photons which increase the statistical noise of the recorded events. Using a dual head PET prototype camera, a series of acquisitions was performed in order to investigate the effect of the energy window to the counting rate performance and the image quality and the minimum detectable activity. In addition, the experiments were simulated with GATE, and the results were validated over the experimental. The used activities ranged below 104kBq. The coincidence images were calculated using the focal plane tomography method. Very good agreement between experimental and simulated results was demonstrated and a well validated model of 176Lu simulation is available. In addition the minimum detectable activity of the system was found to be approximately 13kBq, when a linear capillary source and a 450-650keV energy window were used. Using a wider energy window, 380-650keV, and a cylindrical water phantom with diameter (4cm) we observed a positive impact one image quality at low activities, in terms of SNR. Even thought the rise on the scattered photons was not negligible the positive impact on the simulated true events was considered as a the driving factor.

Original languageEnglish
Title of host publication2013 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013
PublisherInstitute of Electrical and Electronics Engineers Inc.
ISBN (Print)9781479905348
DOIs
StatePublished - 2013
Externally publishedYes
Event2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013 - Seoul, Korea, Republic of
Duration: 27 Oct 20132 Nov 2013

Publication series

NameIEEE Nuclear Science Symposium Conference Record
ISSN (Print)1095-7863

Conference

Conference2013 60th IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2013
Country/TerritoryKorea, Republic of
CitySeoul
Period27/10/132/11/13

Keywords

  • GATE
  • LSO
  • SNR
  • dual head PET
  • minimum detectable activity

Fingerprint

Dive into the research topics of '176Lu effect on the minimum detectable activity limits for a dual head, LSO: Ce based, PET system'. Together they form a unique fingerprint.

Cite this