TY - JOUR
T1 - Simultaneous determination of etoposide and a piperine analogue (PA-1) by UPLC-qTOF-MS
T2 - Evidence that PA-1 enhances the oral bioavailability of etoposide in mice
AU - Sachin, B. S.
AU - Najar, I. A.
AU - Sharma, S. C.
AU - Verma, M. K.
AU - Reddy, M. V.
AU - Anand, R.
AU - Khajuria, R. K.
AU - Koul, S.
AU - Johri, R. K.
N1 - Funding Information:
The financial grant from Council for Scientific and Industrial Research (CSIR), New Delhi, India , to B.S. Sachin is highly acknowledged.
PY - 2010/3/15
Y1 - 2010/3/15
N2 - In the present investigation, a UPLC-qTOF-MS/MS method has been developed for the simultaneous determination of etoposide and a piperine analogue, namely, 4-ethyl 5-(3,4-methylenedioxyphenyl)-2E,4E-pentadienoic acid piperidide (PA-1). The analytes were separated on a reverse phase C18 column using methanol-water (72:28, v/v) mobile phase with a flow rate of 250 μL/min. The qTOF-MS was operated under multiple reaction monitoring mode using electro-spray ionization (ESI) technique with positive ion polarity. The major product ions for etoposide and PA-1 were at m/z 185.1350 and 164.1581, respectively. The recovery of the analytes from mouse plasma was optimized using solid phase extraction technique. The total run time was 6 min and the elution of etoposide and PA-1 occurred at 1.24 and 2.84 min, respectively. The calibration curves of etoposide as well as PA-1 were linear over the concentration range of 2-1000 ng/mL (r2, 0.9829), and 1-1000 ng/mL (r2, 0.9989), respectively. For etoposide intra-assay and inter-assay accuracy in terms of % bias was in between -7.65 to +6.26, and -7.83 to +5.99, respectively. For PA-1 intra-assay and inter-assay accuracy in terms of % bias was in between -7.01 to +9.10, and -7.36 to +6.71, respectively. The lower limit of quantitation for etoposide and PA-1 were 2.0 and 1.0 ng/mL, respectively. Analytes were stable under various conditions (in autosampler, during freeze-thaw, at room temperature, and under deep-freeze conditions). The method was used for a pharmacokinetic study which showed that PA-1 enhanced the oral bioavailability of etoposide in mice by 2.32-fold.
AB - In the present investigation, a UPLC-qTOF-MS/MS method has been developed for the simultaneous determination of etoposide and a piperine analogue, namely, 4-ethyl 5-(3,4-methylenedioxyphenyl)-2E,4E-pentadienoic acid piperidide (PA-1). The analytes were separated on a reverse phase C18 column using methanol-water (72:28, v/v) mobile phase with a flow rate of 250 μL/min. The qTOF-MS was operated under multiple reaction monitoring mode using electro-spray ionization (ESI) technique with positive ion polarity. The major product ions for etoposide and PA-1 were at m/z 185.1350 and 164.1581, respectively. The recovery of the analytes from mouse plasma was optimized using solid phase extraction technique. The total run time was 6 min and the elution of etoposide and PA-1 occurred at 1.24 and 2.84 min, respectively. The calibration curves of etoposide as well as PA-1 were linear over the concentration range of 2-1000 ng/mL (r2, 0.9829), and 1-1000 ng/mL (r2, 0.9989), respectively. For etoposide intra-assay and inter-assay accuracy in terms of % bias was in between -7.65 to +6.26, and -7.83 to +5.99, respectively. For PA-1 intra-assay and inter-assay accuracy in terms of % bias was in between -7.01 to +9.10, and -7.36 to +6.71, respectively. The lower limit of quantitation for etoposide and PA-1 were 2.0 and 1.0 ng/mL, respectively. Analytes were stable under various conditions (in autosampler, during freeze-thaw, at room temperature, and under deep-freeze conditions). The method was used for a pharmacokinetic study which showed that PA-1 enhanced the oral bioavailability of etoposide in mice by 2.32-fold.
KW - Bioavailability
KW - Etoposide
KW - Pharmacokinetics
KW - Piperine analogue
KW - UPLC-qTOF-MS/MS
UR - http://www.scopus.com/inward/record.url?scp=77549085128&partnerID=8YFLogxK
U2 - 10.1016/j.jchromb.2010.01.048
DO - 10.1016/j.jchromb.2010.01.048
M3 - Article
C2 - 20176514
AN - SCOPUS:77549085128
SN - 1570-0232
VL - 878
SP - 823
EP - 830
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
IS - 9-10
ER -