TY - JOUR
T1 - Selective anticoagulation with active site blocked factor IXa in synthetic patch vascular repair results in decreased blood loss and operative time
AU - Spanier, Talia B.
AU - Oz, Mehmet C.
AU - Madigan, John D.
AU - Rose, Eric A.
AU - Stern, David M.
AU - Nowygrod, Roman
AU - Schmidt, Ann Marie
PY - 1997
Y1 - 1997
N2 - Heparin has been the mainstay of anti thrombic therapy in arterial repair procedures. With increasing use of synthetic patch angioplasty (polytetrafluoroethylene [PTFE] or Dacron, Medical Products, Flagstaff, AZ) to improve long-term patency and limit aneurysmal dilation, however, the use of heparin has been associated with excessive needle hole bleeding, resulting in time delay in the operating room to achieve hemostasis, as well as clinically significant blood loss. Because of the multiple sites of action of heparin in the coagulation cascade, both intravascular (desired effect) and extravascular (untoward side effect) hemostasis are impaired. The authors therefore tested the hypothesis that selective inhibition of intravascular coagulation, without significant impairment of extravascular hemostasis, would prevent clotting intraluminally while preserving hemostasis at the suture line of the patch graft. The unique position of factor IX/IXa in the coagulation cascade renders its inhibition an ideal target in this setting. The authors prepared active site blocked factor IXa (IXai) using dansyl-Glu- Gly-Arg chloromethylketone, and tested this hypothesis in a New Zealand rabbit aortotomy model with PTFE patch closure using either heparin (25 IU/kg; n = 16) or IXai (300 μg/kg; n = 21). The infrarenal aorta was identified and isolated, the anti coagulant infused, aortic cross clamp placed, and aortotomy repaired with a 2 x 6 mm PTFE patch. After cross-clamp removal, blood loss was measured and time to hemostasis was recorded. Compared with heparin, IXai resulted in significantly reduced blood loss (6.97 ± 4.4 g vs 2.72 ± 2.51 g, respectively, p < 0.008), and time to hemostasis (2,94 ± 0.77 min vs 2.0 ± 0.63 min, respectively, p < 0.003). To assess long-term patency and thrombosis, 12 rabbits (given heparin; n = 6 and IXai; n = 6) were observed for up to 2 months post-operatively. No differences were observed between rabbits treated with heparin or IXai; 100% of the grafts were patent with no differences in degree of intimal hyperplasia by histologic analysis. Together, these data suggest that use of IXai in PTFE vascular repair will safely allow realization of the benefits of long-term patency and decreased aneurysmal dilatation, while eliminating the intraoperative morbidity of needle hole bleeding.
AB - Heparin has been the mainstay of anti thrombic therapy in arterial repair procedures. With increasing use of synthetic patch angioplasty (polytetrafluoroethylene [PTFE] or Dacron, Medical Products, Flagstaff, AZ) to improve long-term patency and limit aneurysmal dilation, however, the use of heparin has been associated with excessive needle hole bleeding, resulting in time delay in the operating room to achieve hemostasis, as well as clinically significant blood loss. Because of the multiple sites of action of heparin in the coagulation cascade, both intravascular (desired effect) and extravascular (untoward side effect) hemostasis are impaired. The authors therefore tested the hypothesis that selective inhibition of intravascular coagulation, without significant impairment of extravascular hemostasis, would prevent clotting intraluminally while preserving hemostasis at the suture line of the patch graft. The unique position of factor IX/IXa in the coagulation cascade renders its inhibition an ideal target in this setting. The authors prepared active site blocked factor IXa (IXai) using dansyl-Glu- Gly-Arg chloromethylketone, and tested this hypothesis in a New Zealand rabbit aortotomy model with PTFE patch closure using either heparin (25 IU/kg; n = 16) or IXai (300 μg/kg; n = 21). The infrarenal aorta was identified and isolated, the anti coagulant infused, aortic cross clamp placed, and aortotomy repaired with a 2 x 6 mm PTFE patch. After cross-clamp removal, blood loss was measured and time to hemostasis was recorded. Compared with heparin, IXai resulted in significantly reduced blood loss (6.97 ± 4.4 g vs 2.72 ± 2.51 g, respectively, p < 0.008), and time to hemostasis (2,94 ± 0.77 min vs 2.0 ± 0.63 min, respectively, p < 0.003). To assess long-term patency and thrombosis, 12 rabbits (given heparin; n = 6 and IXai; n = 6) were observed for up to 2 months post-operatively. No differences were observed between rabbits treated with heparin or IXai; 100% of the grafts were patent with no differences in degree of intimal hyperplasia by histologic analysis. Together, these data suggest that use of IXai in PTFE vascular repair will safely allow realization of the benefits of long-term patency and decreased aneurysmal dilatation, while eliminating the intraoperative morbidity of needle hole bleeding.
UR - http://www.scopus.com/inward/record.url?scp=0031238490&partnerID=8YFLogxK
U2 - 10.1097/00002480-199709000-00036
DO - 10.1097/00002480-199709000-00036
M3 - Article
C2 - 9360098
AN - SCOPUS:0031238490
SN - 1058-2916
VL - 43
SP - M526-M530
JO - ASAIO Journal
JF - ASAIO Journal
IS - 5
ER -