TY - JOUR
T1 - Safety and technical efficacy of over-the-wire balloons for the treatment of subarachnoid hemorrhage-induced cerebral vasospasm.
AU - Terry, Anna
AU - Zipfel, Gregory
AU - Milner, Eric
AU - Cross, De Witte T.
AU - Moran, Christopher J.
AU - Diringer, Michael N.
AU - Dacey, Ralph G.
AU - Derdeyn, Colin P.
PY - 2006
Y1 - 2006
N2 - OBJECT: Over the past decade, low-pressure, flow-directed balloons have been replaced by over-the-wire balloons in the treatment of vasospasm induced by subarachnoid hemorrhage (SAH). The authors assess the procedural safety and technical efficacy of these newer devices. METHODS: Seventy-five patients who underwent 85 balloon angioplasty procedures for the treatment of SAH-induced vasospasm were identified from a prospective quality-assurance database. Medical records and angiographic reports were reviewed for evidence of procedural complications and technical efficacy. No vessel rupture or perforation occurred, but thromboembolic complications were noted in four (4.7%) of the 85 procedures. Balloon angioplasty was frequently attempted and successfully accomplished in the distal internal carotid (100%), proximal middle cerebral (94%), vertebral (73%), and basilar (88%) arteries. Severe narrowing was present in 89 proximal anterior cerebral arteries. Angioplasty was attempted in 41 of these vessels and was successful in only 14 (34%). In 19 of the 27 unsuccessful attempts, the balloon could not be advanced over the wire due to severe vasospasm or unfavorable vessel angle. Follow-up angiography in a subset of patients demonstrated that severe recurrent vasospasm occurred in 15 (13%) of 116 vessels studied after angioplasty. CONCLUSIONS: Over-the-wire balloons involve a low risk for vessel rupture. The anterior cerebral artery remains difficult to access and successfully treat with current devices. Further improvements in balloon design, such as smaller inflated diameters and better tracking, are necessary. Finally, thromboembolic complications remain an important concern, and severe vasospasm may recur after balloon angioplasty.
AB - OBJECT: Over the past decade, low-pressure, flow-directed balloons have been replaced by over-the-wire balloons in the treatment of vasospasm induced by subarachnoid hemorrhage (SAH). The authors assess the procedural safety and technical efficacy of these newer devices. METHODS: Seventy-five patients who underwent 85 balloon angioplasty procedures for the treatment of SAH-induced vasospasm were identified from a prospective quality-assurance database. Medical records and angiographic reports were reviewed for evidence of procedural complications and technical efficacy. No vessel rupture or perforation occurred, but thromboembolic complications were noted in four (4.7%) of the 85 procedures. Balloon angioplasty was frequently attempted and successfully accomplished in the distal internal carotid (100%), proximal middle cerebral (94%), vertebral (73%), and basilar (88%) arteries. Severe narrowing was present in 89 proximal anterior cerebral arteries. Angioplasty was attempted in 41 of these vessels and was successful in only 14 (34%). In 19 of the 27 unsuccessful attempts, the balloon could not be advanced over the wire due to severe vasospasm or unfavorable vessel angle. Follow-up angiography in a subset of patients demonstrated that severe recurrent vasospasm occurred in 15 (13%) of 116 vessels studied after angioplasty. CONCLUSIONS: Over-the-wire balloons involve a low risk for vessel rupture. The anterior cerebral artery remains difficult to access and successfully treat with current devices. Further improvements in balloon design, such as smaller inflated diameters and better tracking, are necessary. Finally, thromboembolic complications remain an important concern, and severe vasospasm may recur after balloon angioplasty.
UR - http://www.scopus.com/inward/record.url?scp=33750583760&partnerID=8YFLogxK
U2 - 10.3171/foc.2006.21.3.14
DO - 10.3171/foc.2006.21.3.14
M3 - Article
C2 - 17029338
AN - SCOPUS:33750583760
SN - 1092-0684
VL - 21
SP - E14
JO - Neurosurgical Focus
JF - Neurosurgical Focus
IS - 3
ER -