TY - JOUR
T1 - Right ventricular dysfunction and organ failure in left ventricular assist device recipients
T2 - A continuing problem
AU - Kavarana, Minoo N.
AU - Pessin-Minsley, Melissa S.
AU - Urtecho, Jacqueline
AU - Catanese, Katharine A.
AU - Flannery, Margaret
AU - Oz, Mehmet C.
AU - Naka, Yoshifumi
PY - 2002
Y1 - 2002
N2 - Background. Although right ventricular assist device (RVAD) Use has declined with the introduction of inhaled nitric oxide and phosphodiesterase inhibitors (type III), right ventricular dysfunction (RVD) is still a serious problem in patients receiving left ventricular assist devices (LVAD). Methods. We retrospectively analyzed Thoratec Vented Electrical LVAD recipients between June 1996 and September 1999. RVD was defined as inotropic requirement 14 days or more or need for RVAD postoperatively, or both. Results. Sixty-nine LVAD recipients were analyzed. Twenty-one patients (30.4%) had RVD, with 1 patient requiring RVAD insertion, and there were 48 non-RVD patients. There were no significant differences between both groups for age, sex, etiology of congestive heart failure, days of support, and preoperative hemodynamics. Preoperative right ventricle stroke work index (mm Hg·m-2· L-1 had a trend toward being lower in the RVD group (4.1 ± 3.2 versus 6.1 ± 3.7, p = 0.06). A higher preoperative total bilirubin (mg/dL) was noticed in the RVD group (4.0 ± 5.2 versus 2.1 ± 1.7). The RVD group had a higher postoperative creatinine (2.2 ± 1.4 mg/dL versus 1.5 ± 0.8 mg/dL), incidence of continuous venovenous hemofiltration dialysis (73% versus 26%), transfusion of packed red blood cells (43.2 ± 28.6 units versus 24.7 ± 18.9 units), platelets (58.6 ± 46.1 units versus 30.2 ± 20.4 units), with longer intensive care unit length of stay (33.6 ± 34.7 days versus 9.1 ± 6.9) and higher mortality (42.8% versus 14.5%). When deaths were excluded, both intensive care unit and postoperative length of stay were significantly longer in the RVD group. Conclusions. RVD in LVAD recipients remains poorly identified and is associated with a high transfusion rate and end organ failure that results in increased intensive care unit and hospital length of stay, and a high mortality rate. Preoperative identification of risk factors for RVD may select patients who would benefit from a biventricular assist device and prevent the subsequent end organ failure.
AB - Background. Although right ventricular assist device (RVAD) Use has declined with the introduction of inhaled nitric oxide and phosphodiesterase inhibitors (type III), right ventricular dysfunction (RVD) is still a serious problem in patients receiving left ventricular assist devices (LVAD). Methods. We retrospectively analyzed Thoratec Vented Electrical LVAD recipients between June 1996 and September 1999. RVD was defined as inotropic requirement 14 days or more or need for RVAD postoperatively, or both. Results. Sixty-nine LVAD recipients were analyzed. Twenty-one patients (30.4%) had RVD, with 1 patient requiring RVAD insertion, and there were 48 non-RVD patients. There were no significant differences between both groups for age, sex, etiology of congestive heart failure, days of support, and preoperative hemodynamics. Preoperative right ventricle stroke work index (mm Hg·m-2· L-1 had a trend toward being lower in the RVD group (4.1 ± 3.2 versus 6.1 ± 3.7, p = 0.06). A higher preoperative total bilirubin (mg/dL) was noticed in the RVD group (4.0 ± 5.2 versus 2.1 ± 1.7). The RVD group had a higher postoperative creatinine (2.2 ± 1.4 mg/dL versus 1.5 ± 0.8 mg/dL), incidence of continuous venovenous hemofiltration dialysis (73% versus 26%), transfusion of packed red blood cells (43.2 ± 28.6 units versus 24.7 ± 18.9 units), platelets (58.6 ± 46.1 units versus 30.2 ± 20.4 units), with longer intensive care unit length of stay (33.6 ± 34.7 days versus 9.1 ± 6.9) and higher mortality (42.8% versus 14.5%). When deaths were excluded, both intensive care unit and postoperative length of stay were significantly longer in the RVD group. Conclusions. RVD in LVAD recipients remains poorly identified and is associated with a high transfusion rate and end organ failure that results in increased intensive care unit and hospital length of stay, and a high mortality rate. Preoperative identification of risk factors for RVD may select patients who would benefit from a biventricular assist device and prevent the subsequent end organ failure.
UR - http://www.scopus.com/inward/record.url?scp=0036189078&partnerID=8YFLogxK
U2 - 10.1016/S0003-4975(01)03406-3
DO - 10.1016/S0003-4975(01)03406-3
M3 - Article
C2 - 11899176
AN - SCOPUS:0036189078
SN - 0003-4975
VL - 73
SP - 745
EP - 750
JO - Annals of Thoracic Surgery
JF - Annals of Thoracic Surgery
IS - 3
ER -