Abstract
Multicentric or multifocal breast cancer is considered as one of the limitations for sentinel lymph node (SLN) localization. We did a retrospective analysis to evaluate the success rate, sensitivity, accuracy, and negative predictive values of SLN localization in multicentric or multifocal breast lesions. Methods: Fifty-nine patients with multifocal or multicentric breast lesions proven by either fine-needle aspiration (19/59), core biopsy (39/59), or lumpectomy (8/59) underwent SLN localization. Of these patients, 46 had SLN localization by both radiocolloid and blue dye, and 13 had SLN localization by radiocolloid alone. Approximately 10 MBq 99mTc-labeled unfiltered sulfur colloid in 0.3-0.4 mL were injected intradermally over the 1 or 2 breast tumor locations 2-4 h before surgery. During surgery, vital blue dye was injected intraparenchymally in 4-6 places around the tumor. All lymph nodes with counts of >10 times that of the background counts, whether or not blue dye positive, and all blue dye-positive lymph nodes, whether or not radiocolloid positive, were excised and labeled accordingly. underwent frozen sectioning and were examined by hematoxylin and eosin and immunohistologic (cytokeratin) staining. Results: Of the 59 patients, 48 had axillary lymph node dissection irrespective of the results of pathologic examination of the SLN. The success rate, sensitivity, negative predictive value, and accuracy were 93%, 100%, 100%, and 100% using the radiocolloid probe, 87%, 100%, 100%, and 100% using blue dye, and 93.5%, 100%, 100%, and 100% using combined methods, respectively. Concordance between blue dye and radiocolloid was 91% (the incidence of the number of sentinel nodes detected was 37.5%, 30.3%, 10.7%, and 21.4% for 1, 2, 3, and 4 or more lymph nodes, respectively). Metastatic lymph node involvement was found in 39.5% of patients. Conclusion: The sentinel node localization approach showed a high negative predictive value in breast cancer patients with multifocal or multicentric lesions, contrary to the common belief of significant false-negative results in these patients.
| Original language | English |
|---|---|
| Pages (from-to) | 7-10 |
| Number of pages | 4 |
| Journal | Journal of Nuclear Medicine |
| Volume | 44 |
| Issue number | 1 |
| State | Published - 1 Jan 2003 |
Keywords
- Isosulfan blue vital dye
- Multifocal or multicentric breast cancer
- Sentinel lymph node
- Tc-sulfur colloid
- γ-probe
Fingerprint
Dive into the research topics of 'Retrospective analysis of sentinel node localization in multifocal, multicentric, palpable, or nonpalpable breast cancer'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver