TY - JOUR
T1 - Reproducibility assessment of neuromelanin-sensitive magnetic resonance imaging protocols for region-of-interest and voxelwise analyses
AU - Wengler, Kenneth
AU - He, Xiang
AU - Abi-Dargham, Anissa
AU - Horga, Guillermo
N1 - Publisher Copyright:
© 2019 Elsevier Inc.
PY - 2020/3
Y1 - 2020/3
N2 - Neuromelanin-sensitive MRI (NM-MRI) provides a noninvasive measure of the content of neuromelanin (NM), a product of dopamine metabolism that accumulates with age in dopamine neurons of the substantia nigra (SN). NM-MRI has been validated as a measure of both dopamine neuron loss, with applications in neurodegenerative disease, and dopamine function, with applications in psychiatric disease. Furthermore, a voxelwise-analysis approach has been validated to resolve substructures, such as the ventral tegmental area (VTA), within midbrain dopaminergic nuclei thought to have distinct anatomical targets and functional roles. NM-MRI is thus a promising tool that could have diverse research and clinical applications to noninvasively interrogate in vivo the dopamine system in neuropsychiatric illness. Although a test-retest reliability study by Langley et al. using the standard NM-MRI protocol recently reported high reliability, a systematic and comprehensive investigation of the performance of the method for various acquisition parameters and preprocessing methods has not been conducted. In particular, most previous studies used relatively thick MRI slices (~3 mm), compared to the typical in-plane resolution (~0.5 mm) and to the height of the SN (~15 mm), to overcome technical limitations such as specific absorption rate and signal-to-noise ratio, at the cost of partial-volume effects. Here, we evaluated the effect of various acquisition and preprocessing parameters on the strength and test-retest reliability of the NM-MRI signal to determine optimized protocols for both region-of-interest (including whole SN-VTA complex and atlas-defined dopaminergic nuclei) and voxelwise measures. Namely, we determined a combination of parameters that optimizes the strength and reliability of the NM-MRI signal, including acquisition time, slice-thickness, spatial-normalization software, and degree of spatial smoothing. Using a newly developed, detailed acquisition protocol, across two scans separated by 13 days on average, we obtained intra-class correlation values indicating excellent reliability and high contrast, which could be achieved with a different set of parameters depending on the measures of interest and experimental constraints such as acquisition time. Based on this, we provide detailed guidelines covering acquisition through analysis and recommendations for performing NM-MRI experiments with high quality and reproducibility. This work provides a foundation for the optimization and standardization of NM-MRI, a promising MRI approach with growing applications throughout clinical and basic neuroscience.
AB - Neuromelanin-sensitive MRI (NM-MRI) provides a noninvasive measure of the content of neuromelanin (NM), a product of dopamine metabolism that accumulates with age in dopamine neurons of the substantia nigra (SN). NM-MRI has been validated as a measure of both dopamine neuron loss, with applications in neurodegenerative disease, and dopamine function, with applications in psychiatric disease. Furthermore, a voxelwise-analysis approach has been validated to resolve substructures, such as the ventral tegmental area (VTA), within midbrain dopaminergic nuclei thought to have distinct anatomical targets and functional roles. NM-MRI is thus a promising tool that could have diverse research and clinical applications to noninvasively interrogate in vivo the dopamine system in neuropsychiatric illness. Although a test-retest reliability study by Langley et al. using the standard NM-MRI protocol recently reported high reliability, a systematic and comprehensive investigation of the performance of the method for various acquisition parameters and preprocessing methods has not been conducted. In particular, most previous studies used relatively thick MRI slices (~3 mm), compared to the typical in-plane resolution (~0.5 mm) and to the height of the SN (~15 mm), to overcome technical limitations such as specific absorption rate and signal-to-noise ratio, at the cost of partial-volume effects. Here, we evaluated the effect of various acquisition and preprocessing parameters on the strength and test-retest reliability of the NM-MRI signal to determine optimized protocols for both region-of-interest (including whole SN-VTA complex and atlas-defined dopaminergic nuclei) and voxelwise measures. Namely, we determined a combination of parameters that optimizes the strength and reliability of the NM-MRI signal, including acquisition time, slice-thickness, spatial-normalization software, and degree of spatial smoothing. Using a newly developed, detailed acquisition protocol, across two scans separated by 13 days on average, we obtained intra-class correlation values indicating excellent reliability and high contrast, which could be achieved with a different set of parameters depending on the measures of interest and experimental constraints such as acquisition time. Based on this, we provide detailed guidelines covering acquisition through analysis and recommendations for performing NM-MRI experiments with high quality and reproducibility. This work provides a foundation for the optimization and standardization of NM-MRI, a promising MRI approach with growing applications throughout clinical and basic neuroscience.
KW - NM-MRI
KW - Neuromelanin
KW - Substantia nigra
KW - Test-retest
KW - Ventral tegmental area
KW - Voxelwise analysis
UR - http://www.scopus.com/inward/record.url?scp=85076684902&partnerID=8YFLogxK
U2 - 10.1016/j.neuroimage.2019.116457
DO - 10.1016/j.neuroimage.2019.116457
M3 - Article
C2 - 31841683
AN - SCOPUS:85076684902
SN - 1053-8119
VL - 208
JO - NeuroImage
JF - NeuroImage
M1 - 116457
ER -