TY - JOUR
T1 - Replacing the ascending aorta and aortic valve for acute prosthetic valve endocarditis
T2 - Is using prosthetic material contraindicated?
AU - Hagl, Christian
AU - Galla, Jan D.
AU - Lansman, Steven L.
AU - Fink, Daniel
AU - Bodian, Carol A.
AU - Spielvogel, David
AU - Griepp, Randall B.
PY - 2002/11/1
Y1 - 2002/11/1
N2 - Background. The use of prosthetic material (rather than a homograft) for ascending aorta/aortic valve replacement (Bentall procedure) in cases of acute prosthetic valve endocarditis is controversial. We report favorable results using this technique almost exclusively (a homograft was used in only 3 patients with hematological problems) during a 12-year interval. Methods. Twenty-eight patients (55 ± 14 years; 22 male) underwent a Bentall procedure for acute prosthetic valve endocarditis between 1988 and 2000. Twenty-five patients had undergone previous aortic valve replacement (1 with concomitant mitral valve replacement, 4 with coronary artery bypass grafting), and 3 had a previous Bentall operation. The median interval between initial surgery and reoperation was 13 months (range, 1 to 106). Sixty-eight percent of operations were urgent or emergencies. Ninety-three percent of patients had significant aortic regurgitation; complete annuloaortic dehiscence occurred in 71%, and in 57%, an abscess was found. Causative organisms were identified in 25 of 28 patients: Staphylococcus epidermidis (9), Staphylococcus aureus (7), Streptococcus viridans (6), Pseudomonas (2), and Legionella (1). Results. Twenty-three patients had mechanical and 5 had biological valves implanted during the Bentall procedure. Hypothermic circulatory arrest was used in 64%. Hospital mortality was 11%: there was one intraoperative death, and two before discharge (one cardiac, one sepsis). Eighty-nine percent survived without stroke. During follow-up (median, 44.5 months; complete in 92%), 1 patient died of recurrent endocarditis at 4 months. Conclusions. These results indicate that prosthetic root replacement may be superior to use of a homograft for acute aortic prosthetic valve endocarditis, with only a 4% incidence of recurrent endocarditis and reoperation.
AB - Background. The use of prosthetic material (rather than a homograft) for ascending aorta/aortic valve replacement (Bentall procedure) in cases of acute prosthetic valve endocarditis is controversial. We report favorable results using this technique almost exclusively (a homograft was used in only 3 patients with hematological problems) during a 12-year interval. Methods. Twenty-eight patients (55 ± 14 years; 22 male) underwent a Bentall procedure for acute prosthetic valve endocarditis between 1988 and 2000. Twenty-five patients had undergone previous aortic valve replacement (1 with concomitant mitral valve replacement, 4 with coronary artery bypass grafting), and 3 had a previous Bentall operation. The median interval between initial surgery and reoperation was 13 months (range, 1 to 106). Sixty-eight percent of operations were urgent or emergencies. Ninety-three percent of patients had significant aortic regurgitation; complete annuloaortic dehiscence occurred in 71%, and in 57%, an abscess was found. Causative organisms were identified in 25 of 28 patients: Staphylococcus epidermidis (9), Staphylococcus aureus (7), Streptococcus viridans (6), Pseudomonas (2), and Legionella (1). Results. Twenty-three patients had mechanical and 5 had biological valves implanted during the Bentall procedure. Hypothermic circulatory arrest was used in 64%. Hospital mortality was 11%: there was one intraoperative death, and two before discharge (one cardiac, one sepsis). Eighty-nine percent survived without stroke. During follow-up (median, 44.5 months; complete in 92%), 1 patient died of recurrent endocarditis at 4 months. Conclusions. These results indicate that prosthetic root replacement may be superior to use of a homograft for acute aortic prosthetic valve endocarditis, with only a 4% incidence of recurrent endocarditis and reoperation.
UR - http://www.scopus.com/inward/record.url?scp=0036840599&partnerID=8YFLogxK
U2 - 10.1016/S0003-4975(02)04142-5
DO - 10.1016/S0003-4975(02)04142-5
M3 - Article
C2 - 12440665
AN - SCOPUS:0036840599
SN - 0003-4975
VL - 74
SP - S1781-S1785
JO - Annals of Thoracic Surgery
JF - Annals of Thoracic Surgery
IS - 5
ER -