Skip to main navigation Skip to search Skip to main content

Removal of the 2.2.2 cryptand (kryptofix 2.2.2™) from 18FDG by cation exchange

Research output: Contribution to journalArticlepeer-review

22 Scopus citations

Abstract

The 2.2.2 cryptand [4,7,13,16,21,24-hexaoxa-1,10-diazabicyclo-(8.8.8)-hexacosane] was trapped efficiently on Dowex AG50W-X8 (100-200 mesh) cation exchange resin. The concentration of the 2.2.2 cryptand in water with 0.1-2% methanol, or in 1 N HCl, was decreased by a factor of >4000 using 1 mL (1.7 mequiv.) of AG50W-X8 and a flow rate of approx. 2 mL/min. K+, Cs+, Ag+ and Ba2+ forms were about equal in their ability to remove the 2.2.2 cryptand. A disposable cartridge containing 1 mL of hydrogen form resin was inserted into our automated 18FDG system so that the hydrolysate (in 2 cm3 of 1 N HCl) would pass through the cartridge before final purification. No cryptand was detected in the final product as determined by TLC with idoplantinate visualization. The detection limit was 2.5 μg/mL. Less than 3% of the total starting radioactivity was retained by the cation column. Quality assurance tests including apyrogenicity, sterility, radiochemical purity, carbohydrate composition and pH were not compromised by the incorporation of the cryptand removal cartridge.

Original languageEnglish
Pages (from-to)1189-1193
Number of pages5
JournalApplied Radiation and Isotopes
Volume42
Issue number12
DOIs
StatePublished - 1991
Externally publishedYes

Fingerprint

Dive into the research topics of 'Removal of the 2.2.2 cryptand (kryptofix 2.2.2™) from 18FDG by cation exchange'. Together they form a unique fingerprint.

Cite this