Skip to main navigation Skip to search Skip to main content

Relationship between corneal hysteresis and optic nerve parameters measured with spectral domain optical coherence tomography

  • Daniel M. Vu
  • , Fabiana Q. Silva
  • , Sarah J. Haseltine
  • , Joshua R. Ehrlich
  • , Nathan M. Radcliffe

Research output: Contribution to journalArticlepeer-review

25 Scopus citations

Abstract

Background: Corneal hysteresis (CH) has been associated with visual field damage in glaucoma and is related to the velocity of perimetric glaucoma progression. We undertook this investigation to determine whether CH is associated with structural markers of glaucoma damage on spectral domain optical coherence tomography (SD-OCT). Methods: In this retrospective study, 131 patients under glaucoma evaluation were evaluated with SD-OCT (Cirrus; Carl Zeiss Meditec, Dublin, CA) and had CH measurements with the ocular response analyzer (Reichert, Inc., Buffalo, NY). Pearson and partial correlation adjusting for age were preformed to examine the association between CH and variables of interest. Generalized estimating equations were used to construct simple and multiple linear models. Results: While Pearson correlations were modest overall, CH best correlated with mean deviation (MD; r = 0.19) followed by average retinal nerve fiber layer (RNFL) thickness (r = 0.18) and vertical cup to disc ratio (r = -0.11) in the open angle glaucoma group. In univariable models, CH varied as a function of MD (ß = 0.1, 95 % CI 0.03, 0.1; p < 0.001) and of average RNFL thickness (ß = 0.2, 95 % CI 0.1, 0.4; p = 0.001). In a multivariable analysis including MD, age, average RNFL thickness, and glaucoma status, MD (p = 0.001) and age (p < 0.001) retained significant associations with CH. Conclusions: In patients under evaluation and treatment for glaucoma, CH was more closely related to visual field MD than to structural markers of glaucoma damage as measured by SD-OCT.

Original languageEnglish
Pages (from-to)1777-1783
Number of pages7
JournalGraefe's Archive for Clinical and Experimental Ophthalmology
Volume251
Issue number7
DOIs
StatePublished - Jul 2013
Externally publishedYes

Keywords

  • Corneal hysteresis
  • Neuroretinal rim
  • Ocular response analyzer
  • Retinal nerve fiber layer
  • Vertical cup-to-disc ratio
  • Visual field mean deviation

Fingerprint

Dive into the research topics of 'Relationship between corneal hysteresis and optic nerve parameters measured with spectral domain optical coherence tomography'. Together they form a unique fingerprint.

Cite this