T1 - Quantification of airway conductance from noninvasive ventilatory drive in patients with sleep apnea
AU - Tolbert, Thomas M.
AU - Parekh, Ankit
AU - Sands, Scott A.
AU - Mooney, Anne M.
AU - Ayappa, Indu
AU - Rapoport, David M.
N1 - Publisher Copyright:
© 2021 American Physiological Society. All rights reserved.
PY - 2021/11
Y1 - 2021/11
N2 - Upper airway conductance, the ratio of inspiratory airflow to inspiratory effort, quantifies the degree of airway obstruction in hypopneas observed in sleep apnea. We evaluated the ratio of ventilation to noninvasive ventilatory drive as a surrogate of conductance. Furthermore, we developed and tested a refinement of noninvasive drive to incorporate the interactions of inspiratory flow, pressure, and drive to better estimate conductance. Hypopneas were compiled from existing polysomnography studies with esophageal catheterization in 18 patients with known or suspected sleep apnea, totaling 1,517 hypopneas during NREM sleep. For each hypopnea, reference standard conductance was calculated as the ratio of peak inspiratory flow to esophageal pressure change during inspiration. Ventilatory drive was calculated using the algorithm developed by Terrill et al. and then mathematically modified according to the presence or absence of flow limitation to noninvasively estimate esophageal pressure. The ratio of ventilation to ventilatory drive and the ratio of peak inspiratory flow to estimated esophageal pressure were each compared with the reference standard for all hypopneas and for median values from individual patients. Hypopnea ventilation to drive ratios were of limited correlation with the reference standard (R2 = 0.17, individual hypopneas; R2 = 0.03, median patient values). Modification of drive to estimated pressure yielded estimated conductance, which strongly correlated with reference standard conductance (R2 = 0.49, individual hypopneas; R2 = 0.77, median patient values). We conclude that the severity of airway obstruction during hypopneas may be estimated from noninvasive drive by accounting for mechanical effects of flow on pressure.
AB - Upper airway conductance, the ratio of inspiratory airflow to inspiratory effort, quantifies the degree of airway obstruction in hypopneas observed in sleep apnea. We evaluated the ratio of ventilation to noninvasive ventilatory drive as a surrogate of conductance. Furthermore, we developed and tested a refinement of noninvasive drive to incorporate the interactions of inspiratory flow, pressure, and drive to better estimate conductance. Hypopneas were compiled from existing polysomnography studies with esophageal catheterization in 18 patients with known or suspected sleep apnea, totaling 1,517 hypopneas during NREM sleep. For each hypopnea, reference standard conductance was calculated as the ratio of peak inspiratory flow to esophageal pressure change during inspiration. Ventilatory drive was calculated using the algorithm developed by Terrill et al. and then mathematically modified according to the presence or absence of flow limitation to noninvasively estimate esophageal pressure. The ratio of ventilation to ventilatory drive and the ratio of peak inspiratory flow to estimated esophageal pressure were each compared with the reference standard for all hypopneas and for median values from individual patients. Hypopnea ventilation to drive ratios were of limited correlation with the reference standard (R2 = 0.17, individual hypopneas; R2 = 0.03, median patient values). Modification of drive to estimated pressure yielded estimated conductance, which strongly correlated with reference standard conductance (R2 = 0.49, individual hypopneas; R2 = 0.77, median patient values). We conclude that the severity of airway obstruction during hypopneas may be estimated from noninvasive drive by accounting for mechanical effects of flow on pressure.
KW - Central sleep apnea
KW - Hypopnea
KW - Obstructive sleep apnea
KW - Sleep-disordered breathing
KW - Ventilatory drive
UR - https://www.scopus.com/pages/publications/85120065966
U2 - 10.1152/japplphysiol.00387.2021
DO - 10.1152/japplphysiol.00387.2021
M3 - Article
C2 - 34498947
AN - SCOPUS:85120065966
SN - 8750-7587
VL - 131
SP - 1640
EP - 1652
JO - Journal of Applied Physiology
JF - Journal of Applied Physiology
IS - 5
ER -