TY - GEN
T1 - Prediction of intradialytic morbid events in hemodialysis patients by monitoring the second derivative of relative blood volume
AU - Zhu, Fansan
AU - Kotanko, Peter
AU - Thijssen, Stephan
AU - Levin, Nathan W.
PY - 2012
Y1 - 2012
N2 - Intradialytic morbid events (IME) are a major issue affecting hemodialysis (HD) patients. Change in relative blood volume (RBV) reflects change in plasma refilling rate (PRR) and variability of ultrafiltration rate (UFR). However, degree of fluid overload influences this relationship. We propose a method using a second derivative of RBV (SDRBV) model to detect decrease in PRR during HD which is a major factor associated with IME. Forty-five HD patients (age 55.7±14 years, height 167.7±10 cm, Pre HD weight 79.3±16.6 kg) were studied with a total of 245 treatments, with IME occurring in 124 treatments. Predictions of IME with the SDRBV model showed 92 % sensitivity for 124 IME and 43 % specificity of 121 non IME treatments respectively. The average time between prediction and IMEs was 30.8±36 minutes. A high positive predictive value was due to 1) using a low-pass filter to reduce possible interferences in the RBV curve and 2) use of 5 minutes sample frequency to apply the SDRBV model. These results indicate that the SDRBV model is a useful tool in clinical practice to predict and prevent IME.
AB - Intradialytic morbid events (IME) are a major issue affecting hemodialysis (HD) patients. Change in relative blood volume (RBV) reflects change in plasma refilling rate (PRR) and variability of ultrafiltration rate (UFR). However, degree of fluid overload influences this relationship. We propose a method using a second derivative of RBV (SDRBV) model to detect decrease in PRR during HD which is a major factor associated with IME. Forty-five HD patients (age 55.7±14 years, height 167.7±10 cm, Pre HD weight 79.3±16.6 kg) were studied with a total of 245 treatments, with IME occurring in 124 treatments. Predictions of IME with the SDRBV model showed 92 % sensitivity for 124 IME and 43 % specificity of 121 non IME treatments respectively. The average time between prediction and IMEs was 30.8±36 minutes. A high positive predictive value was due to 1) using a low-pass filter to reduce possible interferences in the RBV curve and 2) use of 5 minutes sample frequency to apply the SDRBV model. These results indicate that the SDRBV model is a useful tool in clinical practice to predict and prevent IME.
UR - https://www.scopus.com/pages/publications/84881411217
U2 - 10.1109/EMBC.2012.6346158
DO - 10.1109/EMBC.2012.6346158
M3 - Conference contribution
C2 - 23366119
AN - SCOPUS:84881411217
SN - 9781424441198
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 1226
EP - 1229
BT - 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2012
T2 - 34th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2012
Y2 - 28 August 2012 through 1 September 2012
ER -