Posterolateral Spiral-Shaped One Third Tubular Plate Stabilization for a Long Spiral Fracture of the Lateral Malleolus

Vladimir B. Shur, Vera Malezhik, Viktor Svyatkovsky

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

We present surgical stabilization of a long spiral fibular fracture using a contoured plate, which allows for better fixation of the fracture compared with standard plating. We believe this technique modification provides satisfactory compression and better anatomic orientation to the fibula to facilitate closed fixation.

Original languageEnglish
Pages (from-to)579-582
Number of pages4
JournalJournal of Foot and Ankle Surgery
Volume57
Issue number3
DOIs
StatePublished - 1 May 2018
Externally publishedYes

Keywords

  • ORIF
  • Weber C
  • ankle
  • fibula
  • fracture