T1 - Pearls, pitfalls, and surgical indications of the Intuity TM heart valve: A rapid deployment bioprosthesis. A systematic review of the literature
AU - Dokollari, Aleksander
AU - Torregrossa, Gianluca
AU - Sicouri, Serge
AU - Veshti, Altin
AU - Margaryan, Rafik
AU - Cameli, Matteo
AU - Mandoli, Giulia Elena
AU - Maccherini, Massimo
AU - Montesi, Gianfranco
AU - Cabrucci, Francesco
AU - Coku, Lindita
AU - Arora, Rakesh
AU - Li, Qiao Ri
AU - Bonacchi, Massimo
AU - Gelsomino, Sandro
N1 - Publisher Copyright:
© 2022 Wiley Periodicals LLC.
PY - 2022/12
Y1 - 2022/12
N2 - Objectives: To highlight short- and long-term clinical outcomes of the Intuity TM rapid deployment prosthesis for surgical aortic valve replacement. Methods: We reviewed on PubMed/MEDLINE, Embase, SciELO, LILACS, CCTR/CENTRAL, and Google Scholar for clinical trials, retrospective clinical studies, meta-analysis, and gray literature. Results: Fourty-five clinical studies with 12.714 patients were included in the analysis. Thirty-day mortality ranged from 3.8% for Intuity and 3.9% for transcatheter aortic valve replacement (TAVR). The incidence of paravalvular leak (PVL) (Intuity 0% and TAVR 2.17%), permanent pacemaker implantation (Intuity 11.11% and TAVR 12.5%), stroke (Intuity 2.2% and TAVR 2.6%), myocardial infarction (MI) (Intuity 0% and TAVR 1%), were all higher in the TAVR group. Compared to other sutured bioprosthesis (SB), mortality ranged from 0% to 3.9% for Intuity and 0%−6.9% for SB. Long-term cardiac mortality ranged from 0.9% to 1.55% for Intuity and 1.4%−3.3% for the Perceval valve. The incidence of PVL (Intuity 0.24%−0.7% and Perceval 0%−1%), endocarditis (Intuity 0.2%−0.7% and Perceval 1.6%−6.6%), stroke (Intuity 0.36%−1.4% and Perceval 0%−0.8%), MI (Intuity 0.07%−0.26%), and SVD (Intuity 0.12%−0.7% and Perceval 0%) were comparable. Compared to standard full sternotomy (SFS), minimally invasive surgery (MINV) mortality ranged from 0% to 4.3% for MINV and 0%−2.1% for SFS. Hospital costs outcomes ranged from $37,187−$44,368 for the Intuity, $69,389 for TAVR, and $13,543 for SB. Intuity short-term mortality ranged between 0.9% and 12.4% while long-term mortality ranged between 2.6% and 20%. Conclusions: This manuscript provides a 360° overview of the current rapid deployments, sutureless, and TAVR prosthesis.
AB - Objectives: To highlight short- and long-term clinical outcomes of the Intuity TM rapid deployment prosthesis for surgical aortic valve replacement. Methods: We reviewed on PubMed/MEDLINE, Embase, SciELO, LILACS, CCTR/CENTRAL, and Google Scholar for clinical trials, retrospective clinical studies, meta-analysis, and gray literature. Results: Fourty-five clinical studies with 12.714 patients were included in the analysis. Thirty-day mortality ranged from 3.8% for Intuity and 3.9% for transcatheter aortic valve replacement (TAVR). The incidence of paravalvular leak (PVL) (Intuity 0% and TAVR 2.17%), permanent pacemaker implantation (Intuity 11.11% and TAVR 12.5%), stroke (Intuity 2.2% and TAVR 2.6%), myocardial infarction (MI) (Intuity 0% and TAVR 1%), were all higher in the TAVR group. Compared to other sutured bioprosthesis (SB), mortality ranged from 0% to 3.9% for Intuity and 0%−6.9% for SB. Long-term cardiac mortality ranged from 0.9% to 1.55% for Intuity and 1.4%−3.3% for the Perceval valve. The incidence of PVL (Intuity 0.24%−0.7% and Perceval 0%−1%), endocarditis (Intuity 0.2%−0.7% and Perceval 1.6%−6.6%), stroke (Intuity 0.36%−1.4% and Perceval 0%−0.8%), MI (Intuity 0.07%−0.26%), and SVD (Intuity 0.12%−0.7% and Perceval 0%) were comparable. Compared to standard full sternotomy (SFS), minimally invasive surgery (MINV) mortality ranged from 0% to 4.3% for MINV and 0%−2.1% for SFS. Hospital costs outcomes ranged from $37,187−$44,368 for the Intuity, $69,389 for TAVR, and $13,543 for SB. Intuity short-term mortality ranged between 0.9% and 12.4% while long-term mortality ranged between 2.6% and 20%. Conclusions: This manuscript provides a 360° overview of the current rapid deployments, sutureless, and TAVR prosthesis.
KW - Intuity
KW - TAVR
KW - aortic valve
KW - echocardiography
KW - long-term outcomes
KW - perceval
KW - rapid-deployment
KW - sutured valves
UR - http://www.scopus.com/inward/record.url?scp=85142389185&partnerID=8YFLogxK
U2 - 10.1111/jocs.17231
DO - 10.1111/jocs.17231
M3 - Review article
C2 - 36403259
AN - SCOPUS:85142389185
SN - 0886-0440
VL - 37
SP - 5411
EP - 5417
JO - Journal of Cardiac Surgery
JF - Journal of Cardiac Surgery
IS - 12
ER -