Pearls, pitfalls, and surgical indications of the Intuity TM heart valve: A rapid deployment bioprosthesis. A systematic review of the literature

Aleksander Dokollari, Gianluca Torregrossa, Serge Sicouri, Altin Veshti, Rafik Margaryan, Matteo Cameli, Giulia Elena Mandoli, Massimo Maccherini, Gianfranco Montesi, Francesco Cabrucci, Lindita Coku, Rakesh Arora, Qiao Ri Li, Massimo Bonacchi, Sandro Gelsomino

Research output: Contribution to journalReview articlepeer-review

6 Scopus citations

Abstract

Objectives: To highlight short- and long-term clinical outcomes of the Intuity TM rapid deployment prosthesis for surgical aortic valve replacement. Methods: We reviewed on PubMed/MEDLINE, Embase, SciELO, LILACS, CCTR/CENTRAL, and Google Scholar for clinical trials, retrospective clinical studies, meta-analysis, and gray literature. Results: Fourty-five clinical studies with 12.714 patients were included in the analysis. Thirty-day mortality ranged from 3.8% for Intuity and 3.9% for transcatheter aortic valve replacement (TAVR). The incidence of paravalvular leak (PVL) (Intuity 0% and TAVR 2.17%), permanent pacemaker implantation (Intuity 11.11% and TAVR 12.5%), stroke (Intuity 2.2% and TAVR 2.6%), myocardial infarction (MI) (Intuity 0% and TAVR 1%), were all higher in the TAVR group. Compared to other sutured bioprosthesis (SB), mortality ranged from 0% to 3.9% for Intuity and 0%−6.9% for SB. Long-term cardiac mortality ranged from 0.9% to 1.55% for Intuity and 1.4%−3.3% for the Perceval valve. The incidence of PVL (Intuity 0.24%−0.7% and Perceval 0%−1%), endocarditis (Intuity 0.2%−0.7% and Perceval 1.6%−6.6%), stroke (Intuity 0.36%−1.4% and Perceval 0%−0.8%), MI (Intuity 0.07%−0.26%), and SVD (Intuity 0.12%−0.7% and Perceval 0%) were comparable. Compared to standard full sternotomy (SFS), minimally invasive surgery (MINV) mortality ranged from 0% to 4.3% for MINV and 0%−2.1% for SFS. Hospital costs outcomes ranged from $37,187−$44,368 for the Intuity, $69,389 for TAVR, and $13,543 for SB. Intuity short-term mortality ranged between 0.9% and 12.4% while long-term mortality ranged between 2.6% and 20%. Conclusions: This manuscript provides a 360° overview of the current rapid deployments, sutureless, and TAVR prosthesis.

Original languageEnglish
Pages (from-to)5411-5417
Number of pages7
JournalJournal of Cardiac Surgery
Volume37
Issue number12
DOIs
StatePublished - Dec 2022
Externally publishedYes

Keywords

  • Intuity
  • TAVR
  • aortic valve
  • echocardiography
  • long-term outcomes
  • perceval
  • rapid-deployment
  • sutured valves

Fingerprint

Dive into the research topics of 'Pearls, pitfalls, and surgical indications of the Intuity TM heart valve: A rapid deployment bioprosthesis. A systematic review of the literature'. Together they form a unique fingerprint.

Cite this