Skip to main navigation Skip to search Skip to main content

Novel handheld PET probes provide intraoperative localization of PET-avid lymph nodes

  • Segundo J. González
  • , Joyce Wong
  • , Lorena González
  • , Peter Brader
  • , Maureen Zakowski
  • , Mithat Gönen
  • , Yuman Fong
  • , Vivian E. Strong

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Introduction The accurate intraoperative localization of malignant nodes can pose a challenge to the surgical oncologist. Positron emission tomography (PET) scanning has significantly increased our ability to detect suspicious lesions.We investigated the ability of a novel, handheld tool to evaluate suspicious nodes intraoperatively and to correlate its findings with those seen on preoperative PET scan. Methods Ten nude rats were inoculated with a lymphogenic mesothelioma tumor line and followed weekly with PET scan studies. When suspicious lymph nodes were found, animals were dissected and the intraoperative amount of tissue radiation was analyzed as "tumor- tobackground ratio" (TBR) using the PET probes. Results The intraoperative probe was used to guide dissections and select high-risk nodes based on their specific radiotracer uptake. A total of 52 nodes were harvested; eight of these were suspicious on preoperative PET scan studies. Using a TBR of 2.5, the intraoperative probes were able to localize all suspicious nodes previously seen on PET scan. Both gamma (sensitivity: 100%; specificity: 86%; positive predictive value (PPV): 57%; negative predictive value (NPV): 100%) and beta (sensitivity: 88%; specificity: 91%; PPV: 64%; NPV: 98%) probes showed an excellent area under the curve (AUC) in the receiver operating characteristic analysis (ROC). Both probes had an AUC of 0.95 for localizing suspicious nodes on PET scan. Furthermore, the AUC for detecting malignancy for the gamma probe was 0.90 (95% confidence interval (CI), 0.83-0.99), and for the beta probe it was 0.97 (95% CI, 0.94-1.0), suggesting a better performance of the beta probe for detecting malignancy. Conclusions This novel tool may be used synergistically with the PET scan examination to maximize intraoperative nodal selection and sampling.

Original languageEnglish
Pages (from-to)3214-3221
Number of pages8
JournalSurgical Endoscopy
Volume25
Issue number10
DOIs
StatePublished - Oct 2011
Externally publishedYes

Keywords

  • Beta rays
  • High-energy gamma rays
  • Intraoperative probe
  • Minimally invasive surgery
  • PET probes

Fingerprint

Dive into the research topics of 'Novel handheld PET probes provide intraoperative localization of PET-avid lymph nodes'. Together they form a unique fingerprint.

Cite this