T1 - Noninvasive measurement of cardiac output in hemodialysis patients by task force monitor
T2 - A comparison with the transonic system
AU - Kitzler, Thomas M.
AU - Sergeyeva, Olga
AU - Morris, Alice
AU - Skrabal, Falko
AU - Kotanko, Peter
AU - Levin, Nathan W.
PY - 2007
Y1 - 2007
N2 - Cardiovascular disease is the leading cause of morbidity and mortality in maintenance hemodialysis (MHD) patients. The Transonic (TRS; Transonic Systems, Ithaca, NY) device is frequently used for determination of cardiac output (CO) by an indicator dilution technique. The Task Force Monitor (TFM; CN Systems, Graz, Austria) has gained attention as noninvasive tool for continuous beat-to-beat assessment of cardiovascular variables, including CO by impedance cardiography. Despite its use in cardiology and intensive care settings, the TFM has yet not been validated in dialysis patients.This study compares CO measurements in 12 MHD patients by TFM and TRS. Bland-Altman and regression analysis were used. CO was measured simultaneously by TRS and TFM. Average CO was 5.4 L/min by TRS and 5.0 L/min by TFM, respectively. Bland-Altman analysis revealed no significant systematic differences between the two methods (mean difference: 0.4 L/min; SD: 0.6; p > 0.05). Linear regression analysis showed significant correlation between both techniques (r = 0.802, p = 0.002). The SD of mean individual CO values was 1.1 L/min with TRS and 0.8 L/min with TFM, respectively.CO measured by TFM and TRS does not differ significantly, thus making the TFM an attractive noninvasive tool for the continuous beat-to-beat assessment of CO in MHD patients.
AB - Cardiovascular disease is the leading cause of morbidity and mortality in maintenance hemodialysis (MHD) patients. The Transonic (TRS; Transonic Systems, Ithaca, NY) device is frequently used for determination of cardiac output (CO) by an indicator dilution technique. The Task Force Monitor (TFM; CN Systems, Graz, Austria) has gained attention as noninvasive tool for continuous beat-to-beat assessment of cardiovascular variables, including CO by impedance cardiography. Despite its use in cardiology and intensive care settings, the TFM has yet not been validated in dialysis patients.This study compares CO measurements in 12 MHD patients by TFM and TRS. Bland-Altman and regression analysis were used. CO was measured simultaneously by TRS and TFM. Average CO was 5.4 L/min by TRS and 5.0 L/min by TFM, respectively. Bland-Altman analysis revealed no significant systematic differences between the two methods (mean difference: 0.4 L/min; SD: 0.6; p > 0.05). Linear regression analysis showed significant correlation between both techniques (r = 0.802, p = 0.002). The SD of mean individual CO values was 1.1 L/min with TRS and 0.8 L/min with TFM, respectively.CO measured by TFM and TRS does not differ significantly, thus making the TFM an attractive noninvasive tool for the continuous beat-to-beat assessment of CO in MHD patients.
UR - http://www.scopus.com/inward/record.url?scp=34648852334&partnerID=8YFLogxK
U2 - 10.1097/MAT.0b013e31812e6a90
DO - 10.1097/MAT.0b013e31812e6a90
M3 - Article
C2 - 17885328
AN - SCOPUS:34648852334
SN - 1058-2916
VL - 53
SP - 561
EP - 565
JO - ASAIO Journal
JF - ASAIO Journal
IS - 5
ER -