TY - JOUR
T1 - No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction
T2 - a meta-analysis
AU - Vedantam, Shyam
AU - Shah, Rahil
AU - Bhalla, Sean
AU - Kumar, Shria
AU - Amin, Sunil
N1 - Publisher Copyright:
Copyright © 2023 Korean Society of Gastrointestinal Endoscopy.
PY - 2023/5
Y1 - 2023/5
N2 - Background/Aims: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. Methods: Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed. Results: Thirteen studies were included. The 15 mm and 20 mm LAMS had pooled technical success rates of 93.2% (95% confidence interval [CI], 90.5%-95.2%) and 92.1% (95% CI, 68.4%-98.4%), clinical success rates of 88.6% (95% CI, 85.4%-91.1%) and 89.6% (95% CI, 79.0%-95.1%), adverse event rates of 11.4% (95% CI, 8.1%-15.9%) and 14.7% (95% CI, 4.4%-39.1%), and reintervention rates of 10.3% (95% CI, 6.7%-15.4%) and 3.5% (95% CI, 1.6%-7.6%), respectively. Subgroup analysis revealed no significant differences in technical success, clinical success, or adverse event rates. An increased need for reintervention was noted in the 15 mm stent group (pooled odds ratio, 3.59; 95% CI, 1.40-9.18; p=0.008). Conclusions: No differences were observed in the technical, clinical, or adverse event rates between 15 and 20 mm LAMS use in EUS-GE. An increased need for reintervention is possible when using a 15 mm stent compared to when using a 20 mm stent.
AB - Background/Aims: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. Methods: Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed. Results: Thirteen studies were included. The 15 mm and 20 mm LAMS had pooled technical success rates of 93.2% (95% confidence interval [CI], 90.5%-95.2%) and 92.1% (95% CI, 68.4%-98.4%), clinical success rates of 88.6% (95% CI, 85.4%-91.1%) and 89.6% (95% CI, 79.0%-95.1%), adverse event rates of 11.4% (95% CI, 8.1%-15.9%) and 14.7% (95% CI, 4.4%-39.1%), and reintervention rates of 10.3% (95% CI, 6.7%-15.4%) and 3.5% (95% CI, 1.6%-7.6%), respectively. Subgroup analysis revealed no significant differences in technical success, clinical success, or adverse event rates. An increased need for reintervention was noted in the 15 mm stent group (pooled odds ratio, 3.59; 95% CI, 1.40-9.18; p=0.008). Conclusions: No differences were observed in the technical, clinical, or adverse event rates between 15 and 20 mm LAMS use in EUS-GE. An increased need for reintervention is possible when using a 15 mm stent compared to when using a 20 mm stent.
KW - Endoscopic ultrasound
KW - Gastric bypass
KW - Gastric outlet obstruction
KW - Gastrojejunostomy
KW - Lumen apposing metal stent
UR - http://www.scopus.com/inward/record.url?scp=85164612572&partnerID=8YFLogxK
U2 - 10.5946/ce.2022.299
DO - 10.5946/ce.2022.299
M3 - Review article
AN - SCOPUS:85164612572
SN - 2234-2400
VL - 56
SP - 298
EP - 307
JO - Clinical Endoscopy
JF - Clinical Endoscopy
IS - 3
ER -