TY - JOUR
T1 - Nitroglycerin to Ameliorate Coronary Artery Spasm During Focal Pulsed-Field Ablation for Atrial Fibrillation
AU - Malyshev, Yury
AU - Neuzil, Petr
AU - Petru, Jan
AU - Funasako, Moritoshi
AU - Hala, Pavel
AU - Kopriva, Karel
AU - Schneider, Christopher
AU - Achyutha, Anitha
AU - Vanderper, Annelies
AU - Musikantow, Daniel
AU - Turagam, Mohit
AU - Dukkipati, Srinivas R.
AU - Reddy, Vivek Y.
N1 - Publisher Copyright:
© 2024 American College of Cardiology Foundation
PY - 2024/5
Y1 - 2024/5
N2 - Background: In treating atrial fibrillation, pulsed-field ablation (PFA) has comparable efficacy to conventional thermal ablation, but with important safety advantages: no esophageal injury or pulmonary vein stenosis, and rare phrenic nerve injury. However, when PFA is delivered in proximity to coronary arteries using a pentaspline catheter, which generates a broad electrical field, severe vasospasm can be provoked. Objectives: The authors sought to study the vasospastic potential of a focal PFA catheter with a narrower electrical field and develop a preventive strategy with nitroglycerin. Methods: During atrial fibrillation ablation, a focal PFA catheter was used for cavotricuspid isthmus ablation. Angiography of the right coronary artery (some with fractional flow reserve measurement) was performed before, during, and after PFA. Beyond no nitroglycerin (n = 5), and a few testing strategies (n = 8), 2 primary nitroglycerin administration strategies were studied: 1) multiple boluses (3-2 mg every 2 min) into the right atrium (n = 10), and 2) a bolus (3 mg) into the right atrium with continuous peripheral intravenous infusion (1 mg/min; n = 10). Results: Without nitroglycerin, cavotricuspid isthmus ablation provoked moderate-severe vasospasm in 4 of 5 (80%) patients (fractional flow reserve 0.71 ± 0.08). With repetitive nitroglycerin boluses, severe spasm did not occur, and mild-moderate vasospasm occurred in only 2 of 10 (20%). Using the bolus + infusion strategy, severe and mild-moderate spasm occurred in 1 and 3 of 10 patients (aggregate 40%). No patient had ST-segment changes. Conclusions: Ablation of the cavotricuspid isthmus using a focal PFA catheter routinely provokes right coronary vasospasm. Pretreatment with high doses of parenteral nitroglycerin prevents severe spasm.
AB - Background: In treating atrial fibrillation, pulsed-field ablation (PFA) has comparable efficacy to conventional thermal ablation, but with important safety advantages: no esophageal injury or pulmonary vein stenosis, and rare phrenic nerve injury. However, when PFA is delivered in proximity to coronary arteries using a pentaspline catheter, which generates a broad electrical field, severe vasospasm can be provoked. Objectives: The authors sought to study the vasospastic potential of a focal PFA catheter with a narrower electrical field and develop a preventive strategy with nitroglycerin. Methods: During atrial fibrillation ablation, a focal PFA catheter was used for cavotricuspid isthmus ablation. Angiography of the right coronary artery (some with fractional flow reserve measurement) was performed before, during, and after PFA. Beyond no nitroglycerin (n = 5), and a few testing strategies (n = 8), 2 primary nitroglycerin administration strategies were studied: 1) multiple boluses (3-2 mg every 2 min) into the right atrium (n = 10), and 2) a bolus (3 mg) into the right atrium with continuous peripheral intravenous infusion (1 mg/min; n = 10). Results: Without nitroglycerin, cavotricuspid isthmus ablation provoked moderate-severe vasospasm in 4 of 5 (80%) patients (fractional flow reserve 0.71 ± 0.08). With repetitive nitroglycerin boluses, severe spasm did not occur, and mild-moderate vasospasm occurred in only 2 of 10 (20%). Using the bolus + infusion strategy, severe and mild-moderate spasm occurred in 1 and 3 of 10 patients (aggregate 40%). No patient had ST-segment changes. Conclusions: Ablation of the cavotricuspid isthmus using a focal PFA catheter routinely provokes right coronary vasospasm. Pretreatment with high doses of parenteral nitroglycerin prevents severe spasm.
KW - atrial fibrillation
KW - catheter ablation
KW - cavotricuspid isthmus
KW - cavotricuspid isthmus ablation
KW - nitroglycerin
KW - pulsed field ablation
KW - spasm
KW - vasospasm
UR - http://www.scopus.com/inward/record.url?scp=85187574086&partnerID=8YFLogxK
U2 - 10.1016/j.jacep.2023.12.015
DO - 10.1016/j.jacep.2023.12.015
M3 - Article
C2 - 38385916
AN - SCOPUS:85187574086
SN - 2405-500X
VL - 10
SP - 885
EP - 896
JO - JACC: Clinical Electrophysiology
JF - JACC: Clinical Electrophysiology
IS - 5
ER -