TY - JOUR
T1 - Morbidity and mortality of UNOS status 1B cardiac transplant candidates at home
AU - Lang, Chim C.
AU - Hankins, Shelley
AU - Hauff, Helen
AU - Maybaum, Simon
AU - Edwards, Niloo
AU - Mancini, Donna M.
PY - 2003/4/1
Y1 - 2003/4/1
N2 - Background: On January 20, 1999, UNOS listing regulations changed, allowing stable patients on inotropic support (Status IB) to be discharged home until cardiac transplant. The outcome, morbidity and cost savings of this new strategy has not been evaluated. Methods: From 1/20/99 through 1/1/01, 155 patients were classified as UNOS Status 1B at our institution; 64 patients were never discharged and 91 were discharged home. Criteria for discharge were hemodynamic stability on low-dose, single-agent parenteral inotropic infusion, defined as dobutamine at a dose <7.5 μg/kg/min or milrinone <0.5 μg/kg/min. Data on re-admissions were collected prospectively. The frequency of complex ventricular arrhythmias was evaluated in a sub-group discharged with external or internal cardiodefibrillators (n = 38). Results: Total Status I time to transplant for the 91 discharged patients was 139 ± 91 days, with 87 ± 67 days spent at home. Inpatient time to transplant was still high, with a mean of 51 ± 45 days. The in-hospital time was comparable to that of the 64 patients who were never discharged (51 ± 41 days). Fifty-nine percent of discharged patients were re-admitted, with 37% of patients requiring more than 1 admission. Sixty-six percent of admissions were for worsening heart failure (CHF), and 34% for infection or occlusion of the indwelling intravenous line. No significant arrhythmic events were recorded in the 38 patients who had internal or external cardiodefibrillators. Two patients died suddenly at home. One patient had declined to wear the external cardiodefibrillator. The other patient was not wearing the defibrillator at the time of the event, and in 634 hours of previous monitoring he had had no events. Conclusions: In UNOS Status 1B patients awaiting cardiac transplant on home inotropic therapy, mortality remains low but the re-admission rate was high. There appeared to be a low incidence of complex ventricular arrhythmias.
AB - Background: On January 20, 1999, UNOS listing regulations changed, allowing stable patients on inotropic support (Status IB) to be discharged home until cardiac transplant. The outcome, morbidity and cost savings of this new strategy has not been evaluated. Methods: From 1/20/99 through 1/1/01, 155 patients were classified as UNOS Status 1B at our institution; 64 patients were never discharged and 91 were discharged home. Criteria for discharge were hemodynamic stability on low-dose, single-agent parenteral inotropic infusion, defined as dobutamine at a dose <7.5 μg/kg/min or milrinone <0.5 μg/kg/min. Data on re-admissions were collected prospectively. The frequency of complex ventricular arrhythmias was evaluated in a sub-group discharged with external or internal cardiodefibrillators (n = 38). Results: Total Status I time to transplant for the 91 discharged patients was 139 ± 91 days, with 87 ± 67 days spent at home. Inpatient time to transplant was still high, with a mean of 51 ± 45 days. The in-hospital time was comparable to that of the 64 patients who were never discharged (51 ± 41 days). Fifty-nine percent of discharged patients were re-admitted, with 37% of patients requiring more than 1 admission. Sixty-six percent of admissions were for worsening heart failure (CHF), and 34% for infection or occlusion of the indwelling intravenous line. No significant arrhythmic events were recorded in the 38 patients who had internal or external cardiodefibrillators. Two patients died suddenly at home. One patient had declined to wear the external cardiodefibrillator. The other patient was not wearing the defibrillator at the time of the event, and in 634 hours of previous monitoring he had had no events. Conclusions: In UNOS Status 1B patients awaiting cardiac transplant on home inotropic therapy, mortality remains low but the re-admission rate was high. There appeared to be a low incidence of complex ventricular arrhythmias.
UR - http://www.scopus.com/inward/record.url?scp=0037382122&partnerID=8YFLogxK
U2 - 10.1016/S1053-2498(02)00570-3
DO - 10.1016/S1053-2498(02)00570-3
M3 - Article
C2 - 12681419
AN - SCOPUS:0037382122
SN - 1053-2498
VL - 22
SP - 419
EP - 426
JO - Journal of Heart and Lung Transplantation
JF - Journal of Heart and Lung Transplantation
IS - 4
ER -