T1 - Meta-analysis of randomized studies comparing intravascular ultrasound versus angiographic guidance of percutaneous coronary intervention in predrug-eluting stent era
AU - Parise, Helen
AU - Maehara, Akiko
AU - Stone, Gregg W.
AU - Leon, Martin B.
AU - Mintz, Gary S.
N1 - Funding Information:
This analysis was supported by an unrestricted grant from Volcano Corporation , Rancho Cordoba, California.
PY - 2011/2/1
Y1 - 2011/2/1
N2 - We conducted a formal meta-analysis of peer-reviewed, published, randomized studies comparing intravascular ultrasound (IVUS)-guidance and angiographic-guided bare metal stent implantation. A total of 8 studies were identified. Because the Balloon Equivalent to Stent (BEST) study was a noninferiority trial designed to compare 2 very different percutaneous coronary intervention strategiesIVUS-guided aggressive balloon angioplasty (with bail-out stenting) and angiographic-guided deliberate bare metal stent implantationit was eliminated. An unadjusted random-effects meta-analysis was used to compare the IVUS-guided and nonIVUS-guided stenting in the 7 remaining studies. A total of 2,193 patients were randomized in 5 multicenter and 2 single-center studies. IVUS guidance was associated with a significantly larger postprocedure angiographic minimum lumen diameter. The mean difference was 0.12 mm (95% confidence interval [CI] 0.06 to 0.18, p <0.0001). IVUS guidance was also associated with a significantly lower rate of 6-month angiographic restenosis (22% vs 29%, odds ratio 0.64, 95% CI 0.42 to 0.96, p = 0.02), a significant reduction in the revascularization rate (13% vs 18%, odds ratio 0.66, 95% CI 0.48 to 0.91, p = 0.004), and overall major adverse cardiac events (19% vs. 23%, odds ratio 0.69, 95% CI 0.49 to 0.97, p = 0.03). However, no significant effect was seen for myocardial infarction (p = 0.51) or mortality (p = 0.18). In conclusion, IVUS guidance for bare metal stent implantation improved the acute procedural results (angiographic minimum lumen diameter) and thereby reduced angiographic restenosis and repeat revascularization and major adverse cardiac events, with a neutral effect on death and myocardial infarction during a follow-up period of 6 months to 2.5 years.
AB - We conducted a formal meta-analysis of peer-reviewed, published, randomized studies comparing intravascular ultrasound (IVUS)-guidance and angiographic-guided bare metal stent implantation. A total of 8 studies were identified. Because the Balloon Equivalent to Stent (BEST) study was a noninferiority trial designed to compare 2 very different percutaneous coronary intervention strategiesIVUS-guided aggressive balloon angioplasty (with bail-out stenting) and angiographic-guided deliberate bare metal stent implantationit was eliminated. An unadjusted random-effects meta-analysis was used to compare the IVUS-guided and nonIVUS-guided stenting in the 7 remaining studies. A total of 2,193 patients were randomized in 5 multicenter and 2 single-center studies. IVUS guidance was associated with a significantly larger postprocedure angiographic minimum lumen diameter. The mean difference was 0.12 mm (95% confidence interval [CI] 0.06 to 0.18, p <0.0001). IVUS guidance was also associated with a significantly lower rate of 6-month angiographic restenosis (22% vs 29%, odds ratio 0.64, 95% CI 0.42 to 0.96, p = 0.02), a significant reduction in the revascularization rate (13% vs 18%, odds ratio 0.66, 95% CI 0.48 to 0.91, p = 0.004), and overall major adverse cardiac events (19% vs. 23%, odds ratio 0.69, 95% CI 0.49 to 0.97, p = 0.03). However, no significant effect was seen for myocardial infarction (p = 0.51) or mortality (p = 0.18). In conclusion, IVUS guidance for bare metal stent implantation improved the acute procedural results (angiographic minimum lumen diameter) and thereby reduced angiographic restenosis and repeat revascularization and major adverse cardiac events, with a neutral effect on death and myocardial infarction during a follow-up period of 6 months to 2.5 years.
UR - http://www.scopus.com/inward/record.url?scp=78951469778&partnerID=8YFLogxK
U2 - 10.1016/j.amjcard.2010.09.030
DO - 10.1016/j.amjcard.2010.09.030
M3 - Article
C2 - 21257001
AN - SCOPUS:78951469778
SN - 0002-9149
VL - 107
SP - 374
EP - 382
JO - American Journal of Cardiology
JF - American Journal of Cardiology
IS - 3
ER -