TY - JOUR
T1 - Mechanical or biologic prostheses for aortic-valve and mitral-valve replacement
AU - Goldstone, Andrew B.
AU - Chiu, Peter
AU - Baiocchi, Michael
AU - Lingala, Bharathi
AU - Patrick, William L.
AU - Fischbein, Michael P.
AU - Woo, Y. Joseph
N1 - Publisher Copyright:
Copyright © 2017 Massachusetts Medical Society. All rights reserved.
PY - 2017/11/9
Y1 - 2017/11/9
N2 - BACKGROUND: In patients undergoing aortic-valve or mitral-valve replacement, either a mechanical or biologic prosthesis is used. Biologic prostheses have been increasingly favored despite limited evidence supporting this practice. METHODS: We compared long-term mortality and rates of reoperation, stroke, and bleeding between inverse-probability-weighted cohorts of patients who underwent primary aortic-valve replacement or mitral-valve replacement with a mechanical or biologic prosthesis in California in the period from 1996 through 2013. Patients were stratified into different age groups on the basis of valve position (aortic vs. mitral valve). RESULTS: From 1996 through 2013, the use of biologic prostheses increased substantially for aortic-valve and mitral-valve replacement, from 11.5% to 51.6% for aortic-valve replacement and from 16.8% to 53.7% for mitral-valve replacement. Among patients who underwent aortic-valve replacement, receipt of a biologic prosthesis was associated with significantly higher 15-year mortality than receipt of a mechanical prosthesis among patients 45 to 54 years of age (30.6% vs. 26.4% at 15 years; hazard ratio, 1.23; 95% confidence interval [CI], 1.02 to 1.48; P = 0.03) but not among patients 55 to 64 years of age. Among patients who underwent mitral-valve replacement, receipt of a biologic prosthesis was associated with significantly higher mortality than receipt of a mechanical prosthesis among patients 40 to 49 years of age (44.1% vs. 27.1%; hazard ratio, 1.88; 95% CI, 1.35 to 2.63; P<0.001) and among those 50 to 69 years of age (50.0% vs. 45.3%; hazard ratio, 1.16; 95% CI, 1.04 to 1.30; P = 0.01). The incidence of reoperation was significantly higher among recipients of a biologic prosthesis than among recipients of a mechanical prosthesis. Patients who received mechanical valves had a higher cumulative incidence of bleeding and, in some age groups, stroke than did recipients of a biologic prosthesis. CONCLUSIONS: The long-term mortality benefit that was associated with a mechanical prosthesis, as compared with a biologic prosthesis, persisted until 70 years of age among patients undergoing mitral-valve replacement and until 55 years of age among those undergoing aortic-valve replacement.
AB - BACKGROUND: In patients undergoing aortic-valve or mitral-valve replacement, either a mechanical or biologic prosthesis is used. Biologic prostheses have been increasingly favored despite limited evidence supporting this practice. METHODS: We compared long-term mortality and rates of reoperation, stroke, and bleeding between inverse-probability-weighted cohorts of patients who underwent primary aortic-valve replacement or mitral-valve replacement with a mechanical or biologic prosthesis in California in the period from 1996 through 2013. Patients were stratified into different age groups on the basis of valve position (aortic vs. mitral valve). RESULTS: From 1996 through 2013, the use of biologic prostheses increased substantially for aortic-valve and mitral-valve replacement, from 11.5% to 51.6% for aortic-valve replacement and from 16.8% to 53.7% for mitral-valve replacement. Among patients who underwent aortic-valve replacement, receipt of a biologic prosthesis was associated with significantly higher 15-year mortality than receipt of a mechanical prosthesis among patients 45 to 54 years of age (30.6% vs. 26.4% at 15 years; hazard ratio, 1.23; 95% confidence interval [CI], 1.02 to 1.48; P = 0.03) but not among patients 55 to 64 years of age. Among patients who underwent mitral-valve replacement, receipt of a biologic prosthesis was associated with significantly higher mortality than receipt of a mechanical prosthesis among patients 40 to 49 years of age (44.1% vs. 27.1%; hazard ratio, 1.88; 95% CI, 1.35 to 2.63; P<0.001) and among those 50 to 69 years of age (50.0% vs. 45.3%; hazard ratio, 1.16; 95% CI, 1.04 to 1.30; P = 0.01). The incidence of reoperation was significantly higher among recipients of a biologic prosthesis than among recipients of a mechanical prosthesis. Patients who received mechanical valves had a higher cumulative incidence of bleeding and, in some age groups, stroke than did recipients of a biologic prosthesis. CONCLUSIONS: The long-term mortality benefit that was associated with a mechanical prosthesis, as compared with a biologic prosthesis, persisted until 70 years of age among patients undergoing mitral-valve replacement and until 55 years of age among those undergoing aortic-valve replacement.
UR - http://www.scopus.com/inward/record.url?scp=85033371772&partnerID=8YFLogxK
U2 - 10.1056/NEJMoa1613792
DO - 10.1056/NEJMoa1613792
M3 - Article
C2 - 29117490
AN - SCOPUS:85033371772
SN - 0028-4793
VL - 377
SP - 1847
EP - 1857
JO - New England Journal of Medicine
JF - New England Journal of Medicine
IS - 19
ER -