TY - JOUR
T1 - Lung cancers diagnosed at annual CT screening
T2 - Volume doubling times
AU - Henschke, Claudia I.
AU - Yankelevitz, David F.
AU - Yip, Rowena
AU - Reeves, Anthony P.
AU - Farooqi, Ali
AU - Xu, Dongming
AU - Smith, James P.
AU - Libby, Daniel M.
AU - Pasmantier, Mark W.
AU - Miettinen, Olli S.
PY - 2012
Y1 - 2012
N2 - Purpose: To empirically address the distribution of the volume doubling time (VDT) of lung cancers diagnosed in repeat annual rounds of computed tomographic (CT) screening in the International Early Lung Cancer Action Program (IELCAP), first and foremost with respect to rates of tumor growth but also in terms of cell types. Materials and Methods: All CT screenings in I-ELCAP from 1993 to 2009 were performed according to HIPAA-compliant protocols approved by the institutional review boards of the collaborating institutions. All instances of first diagnosis of primary lung cancer after a negative screening result 7-18 months earlier were identified, with symptom-prompted diagnoses included. Lesion diameter was calculated by using the measured length and width of each cancer at the time when the nodule was first identified for further work-up and at the time of the most recent prior screening, 7-18 months earlier. The length and width were measured a second time for each cancer, and the geometric mean of the two calculated diameters was used to calculate the VDT. The χ 2 statistic was used to compare the VDT distributions. Results: The median VDT for 111 cancers was 98 days (interquartile range, 108). For 56 (50%) cancers it was less than 100 days, and for three (3%) cancers it was more than 400 days. Adenocarcinoma was the most frequent cell type (50%), followed by squamous cell carcinoma (19%), small cell carcinoma (19%), and others (12%). Lung cancers manifesting as subsolid nodules had significantly longer VDTs than those manifesting as solid nodules (P < .0001). Conclusion: Lung cancers diagnosed in annual repeat rounds of CT screening, as manifest by the VDT and cell-type distributions, are similar to those diagnosed in the absence of screening.
AB - Purpose: To empirically address the distribution of the volume doubling time (VDT) of lung cancers diagnosed in repeat annual rounds of computed tomographic (CT) screening in the International Early Lung Cancer Action Program (IELCAP), first and foremost with respect to rates of tumor growth but also in terms of cell types. Materials and Methods: All CT screenings in I-ELCAP from 1993 to 2009 were performed according to HIPAA-compliant protocols approved by the institutional review boards of the collaborating institutions. All instances of first diagnosis of primary lung cancer after a negative screening result 7-18 months earlier were identified, with symptom-prompted diagnoses included. Lesion diameter was calculated by using the measured length and width of each cancer at the time when the nodule was first identified for further work-up and at the time of the most recent prior screening, 7-18 months earlier. The length and width were measured a second time for each cancer, and the geometric mean of the two calculated diameters was used to calculate the VDT. The χ 2 statistic was used to compare the VDT distributions. Results: The median VDT for 111 cancers was 98 days (interquartile range, 108). For 56 (50%) cancers it was less than 100 days, and for three (3%) cancers it was more than 400 days. Adenocarcinoma was the most frequent cell type (50%), followed by squamous cell carcinoma (19%), small cell carcinoma (19%), and others (12%). Lung cancers manifesting as subsolid nodules had significantly longer VDTs than those manifesting as solid nodules (P < .0001). Conclusion: Lung cancers diagnosed in annual repeat rounds of CT screening, as manifest by the VDT and cell-type distributions, are similar to those diagnosed in the absence of screening.
UR - http://www.scopus.com/inward/record.url?scp=84862507707&partnerID=8YFLogxK
U2 - 10.1148/radiol.12102489
DO - 10.1148/radiol.12102489
M3 - Article
C2 - 22454506
AN - SCOPUS:84862507707
SN - 0033-8419
VL - 263
SP - 578
EP - 583
JO - Radiology
JF - Radiology
IS - 2
ER -