Left atrial function is unchanged by implantable defibrillator shocks on hearts in sinus rhythm

  • Rohan Perera
  • , Jonathan S. Steinberg
  • , Frederick Ehlert
  • , Allen Mogtader
  • , Zak Hillel

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Sixteen patients in sinus rhythm at baseline undergoing implantable cardioverter-defibrillator implantation were monitored with transesophageal echocardiography both before and after direct current cardioverter with currents of 15 to 20 J, for any direct current induced atrial dysfunction. We found no change in the indexes of atrial function or appearance of spontaneous echo contrast in the immediate postshock period by intraoperative transesophageal echocardiography.

Original languageEnglish
Pages (from-to)787-789
Number of pages3
JournalAmerican Journal of Cardiology
Volume81
Issue number6
DOIs
StatePublished - 15 Mar 1998