Abstract
This study describes a novel method of pin care with a Betadine-soaked alcohol pad in conjunction with immobilization to reduce pin site complications in hand fractures treated with exposed Kirschner wires (K-wires). We conducted a retrospective review of all phalangeal and metacarpal fractures from 2010 to 2016 treated with K-wire fixation, a Betadine-soaked alcohol pad, and immobilization in a well-moulded plaster cast. A total of 155 patients with metacarpal or phalangeal fractures were identified, of which 149 were included with 164 fractures treated with 217 exposed K-wires. Overall complication rate was 6.1% (10/164), of which 3 fractures (1.8%) developed infections. Two infections occurred in patients with a history of organ transplantation. The most common complication was stiffness requiring closed manipulation under anesthesia (2.4%, 4/164), resulting in full range of motion in 3 of 4 patients. Exposed K-wires remain an effective method of hand fracture fixation associated with a low complication rate.
Translated title of the contribution | Betadine-Soaked Alcohol Pad and Rigid Immobilization: An Inexpensive and Effective Method to Diminish Infections With Exposed Kirschner Wires in Hand Fractures |
---|---|
Original language | English |
Pages (from-to) | 83-87 |
Number of pages | 5 |
Journal | Plastic Surgery |
Volume | 28 |
Issue number | 2 |
DOIs | |
State | Published - 1 May 2020 |
Keywords
- Betadine
- Kirschner wire
- fracture
- infection
- k-wire
- metacarpal
- percutaneous
- phalangeal