Intrinsic safety explosion-proof system monitoring oxygen concentrations in coke-oven gas

Tianhuai Ding, Fei Zhou, Peng Wang

Research output: Contribution to journalArticlepeer-review

Abstract

An on-line monitoring system was developed to real-timely and accurately measure oxygen concentrations in coke-oven gas to avoid explosion. A weak signal preprocessing unit and an ultra-low-power micro controller unit, MSP430, were used to construct the signal processing system, with a 3.6 V explosion-proof power supply made using current-limiting resistance and epoxy resin filling techniques and with the overall circuit parameters carefully controlled, which insures the system intrinsic safety ranked Ex ia and safe, steady performance in the industrial zone 0. The results of authentication tests and field experiments show that the system meets the practical requirements of coking fields with a precision of ± 0.8%.

Original languageEnglish
Pages (from-to)1956-1958
Number of pages3
JournalQinghua Daxue Xuebao/Journal of Tsinghua University
Volume47
Issue number11
StatePublished - Nov 2007
Externally publishedYes

Keywords

  • Coke-oven gas
  • Explosion-proof power
  • Intrinsic safety
  • Monitoring
  • Oxygen concentration

Fingerprint

Dive into the research topics of 'Intrinsic safety explosion-proof system monitoring oxygen concentrations in coke-oven gas'. Together they form a unique fingerprint.