TY - JOUR
T1 - Initial experience with routine less invasive implantation of HeartMate II left ventricular assist device without median sternotomy
AU - Anyanwu, Anelechi C.
AU - Itagaki, Shinobu
AU - Pinney, Sean
AU - Adams, David H.
N1 - Publisher Copyright:
© The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery.
PY - 2014/12/1
Y1 - 2014/12/1
N2 - OBJECTIVES: Standard implantation of HeartMate II (HMII) left ventricular assist device requires an extended median sternotomy; this incision, while generally well tolerated, may add morbidity in critically ill debilitated patients. We recently adopted a sternum sparing technique for routine HMII implants using a left subcostal incision to create a pocket and access the left ventricular apex, and a right minithoracotomy to access the ascending aorta. METHODS: Retrospective analysis of 40 consecutive patients (M:F 32 : 8; age range 48-77 years; Interagency Registry for Mechanically Assisted Circulatory Support 1 = 8; 2 = 10; 3 or 4 = 22) who underwent implantation of HMII using a non-sternotomy approach in a single institution. RESULTS: HMII insertion was completed with the less invasive technique in all cases with no conversions to full sternotomy. There were no reoperations for bleeding and 70% of patients did not have any intraoperative blood product transfusion. No patient required right ventricular assist device support. Majority of patients (80%) were extubated by postoperative day 1. There were no wound, mediastinal or pocket infections. One patient suffered a new perioperative stroke. Median postoperative hospital stay was 19 days. Operative mortality was 7.5% and 12-month actuarial survival was 86 ± 6%. CONCLUSIONS: Primary HMII implantation without median sternotomy is feasible and can be safely, effectively and routinely applied, using our less invasive approach. Further investigation is necessary to determine whether the non-invasive technique contributed to the low incidence of bleeding, blood transfusion, respiratory morbidity and right ventricular failure seen in this study.
AB - OBJECTIVES: Standard implantation of HeartMate II (HMII) left ventricular assist device requires an extended median sternotomy; this incision, while generally well tolerated, may add morbidity in critically ill debilitated patients. We recently adopted a sternum sparing technique for routine HMII implants using a left subcostal incision to create a pocket and access the left ventricular apex, and a right minithoracotomy to access the ascending aorta. METHODS: Retrospective analysis of 40 consecutive patients (M:F 32 : 8; age range 48-77 years; Interagency Registry for Mechanically Assisted Circulatory Support 1 = 8; 2 = 10; 3 or 4 = 22) who underwent implantation of HMII using a non-sternotomy approach in a single institution. RESULTS: HMII insertion was completed with the less invasive technique in all cases with no conversions to full sternotomy. There were no reoperations for bleeding and 70% of patients did not have any intraoperative blood product transfusion. No patient required right ventricular assist device support. Majority of patients (80%) were extubated by postoperative day 1. There were no wound, mediastinal or pocket infections. One patient suffered a new perioperative stroke. Median postoperative hospital stay was 19 days. Operative mortality was 7.5% and 12-month actuarial survival was 86 ± 6%. CONCLUSIONS: Primary HMII implantation without median sternotomy is feasible and can be safely, effectively and routinely applied, using our less invasive approach. Further investigation is necessary to determine whether the non-invasive technique contributed to the low incidence of bleeding, blood transfusion, respiratory morbidity and right ventricular failure seen in this study.
KW - Blood transfusion
KW - Left ventricular assist device
KW - Minimally invasive surgery
UR - http://www.scopus.com/inward/record.url?scp=84924023593&partnerID=8YFLogxK
U2 - 10.1093/ejcts/ezu044
DO - 10.1093/ejcts/ezu044
M3 - Article
C2 - 24623169
AN - SCOPUS:84924023593
SN - 1010-7940
VL - 46
SP - 985
EP - 990
JO - European Journal of Cardio-thoracic Surgery
JF - European Journal of Cardio-thoracic Surgery
IS - 6
ER -