TY - JOUR
T1 - In-hospital outcomes and usage of embolic protection devices in percutaneous coronary intervention for coronary artery bypass grafts
T2 - Insights from a Japanese nationwide registry
AU - Oba, Yusuke
AU - Inohara, Taku
AU - Takahashi, Masao
AU - Fukutomi, Motoki
AU - Funayama, Hiroshi
AU - Ando, Hirohiko
AU - Kohsaka, Shun
AU - Amano, Tetsuya
AU - Ikari, Yuji
AU - Kario, Kazuomi
N1 - Publisher Copyright:
© 2021 Wiley Periodicals LLC.
PY - 2021/9
Y1 - 2021/9
N2 - Objectives: We evaluated the in-hospital outcomes of percutaneous coronary intervention (PCI) for bypass graft vessels (GV-PCI) compared with those of PCI for native vessels (NV-PCI) using data from the Japanese nationwide coronary intervention registry. Methods: We included PCI patients (N = 748,229) registered between January 2016 and December 2018 from 1,123 centers. We divided patients into three groups: GV-PCI (n = 2,745); NV-PCI with a prior coronary artery bypass graft (pCABG) (n = 23,932); and NV-PCI without pCABG (n = 721,552). Results: GV-PCI implementation was low, and most cases of PCI in pCABG patients were performed in native vessels (89.7%) in contemporary Japanese practice. The risk profile of patients with pCABG was higher than that of those without pCABG. Consequently, GV-PCI patients had a significantly higher in-hospital mortality than NV-PCI patients without pCABG after adjusting for covariates (odds ratio [OR] 2.36, 95% confidence interval [CI] 1.66–3.36, p <.001). Of note, embolic protection devices (EPDs) were used in 18% (n = 383) of PCIs for saphenous vein grafts (SVG-PCI) with a significant variation in its use among institutions (number of PCI: hospitals that had never used an EPD vs. EPD used one or more times = 240 vs. 345, p <.001). The EPDs used in the SVG-PCI group had a significantly lower prevalence of the slow-flow phenomenon after adjusting for covariates (OR 0.45, 95% CI 0.21–0.91, p =.04). Conclusion: GV-PCI is associated with an increased risk of in-hospital mortality. EDP use in SVG-PCI was associated with a low rate of the slow-flow phenomenon. The usage of EPDs during SVG-PCI is low, with a significant variation among institutions.
AB - Objectives: We evaluated the in-hospital outcomes of percutaneous coronary intervention (PCI) for bypass graft vessels (GV-PCI) compared with those of PCI for native vessels (NV-PCI) using data from the Japanese nationwide coronary intervention registry. Methods: We included PCI patients (N = 748,229) registered between January 2016 and December 2018 from 1,123 centers. We divided patients into three groups: GV-PCI (n = 2,745); NV-PCI with a prior coronary artery bypass graft (pCABG) (n = 23,932); and NV-PCI without pCABG (n = 721,552). Results: GV-PCI implementation was low, and most cases of PCI in pCABG patients were performed in native vessels (89.7%) in contemporary Japanese practice. The risk profile of patients with pCABG was higher than that of those without pCABG. Consequently, GV-PCI patients had a significantly higher in-hospital mortality than NV-PCI patients without pCABG after adjusting for covariates (odds ratio [OR] 2.36, 95% confidence interval [CI] 1.66–3.36, p <.001). Of note, embolic protection devices (EPDs) were used in 18% (n = 383) of PCIs for saphenous vein grafts (SVG-PCI) with a significant variation in its use among institutions (number of PCI: hospitals that had never used an EPD vs. EPD used one or more times = 240 vs. 345, p <.001). The EPDs used in the SVG-PCI group had a significantly lower prevalence of the slow-flow phenomenon after adjusting for covariates (OR 0.45, 95% CI 0.21–0.91, p =.04). Conclusion: GV-PCI is associated with an increased risk of in-hospital mortality. EDP use in SVG-PCI was associated with a low rate of the slow-flow phenomenon. The usage of EPDs during SVG-PCI is low, with a significant variation among institutions.
KW - J-PCI
KW - embolic protection device
KW - graft vessel
KW - nationwide coronary intervention registry
KW - saphenous vein graft
UR - http://www.scopus.com/inward/record.url?scp=85104544444&partnerID=8YFLogxK
U2 - 10.1002/ccd.29695
DO - 10.1002/ccd.29695
M3 - Article
C2 - 33861509
AN - SCOPUS:85104544444
SN - 1522-1946
VL - 98
SP - E356-E364
JO - Catheterization and Cardiovascular Interventions
JF - Catheterization and Cardiovascular Interventions
IS - 3