TY - JOUR
T1 - How do i provide leukapheresis products? Blood center experience and evidence for process improvement
AU - Ginzburg, Yelena
AU - Kessler, Debra
AU - Narici, Manlio
AU - Caltabiano, Melinda
AU - Rebosa, Mark
AU - Strauss, Donna
AU - Shaz, Beth
PY - 2013/10
Y1 - 2013/10
N2 - Background The past few decades have seen a resurgence of interest in leukapheresis products to improve the survival of infected patients with neutropenia. These products have a short shelf life and require donor stimulation with dexamethasone before collection. Additionally, a system with good communications and logistical support is essential. A recent survey of blood centers in North America revealed that the majority of centers collecting leukapheresis products use steroid-stimulated donors. The survey results suggested that an analysis of the process and potential process improvement would be of interest to the transfusion medicine community. Study Design and Methods Data from 2008 to 2011 regarding donor selection, donor dexamethasone stimulation, leukapheresis collection, and correlations between potentially pertinent variables for process improvement were analyzed. Results from an analysis of cost are also included. Results We evaluate 432 leukapheresis donations and demonstrate correlations between 1) pre- and poststimulation white blood cell (WBC) count (p < 0.0001), 2) interval (donor stimulation to collection) and poststimulation WBC count (p < 0.0001), and 3) poststimulation WBC count and leukapheresis product granulocyte yield (p < 0.0001). Conclusions Significant improvement in granulocyte quality and yield can be accomplished in dexamethasone-stimulated donors, by selecting eligible donors with relatively high normal prestimulation WBC counts and/or previously good responses to dexamethasone, increasing the duration between dexamethasone stimulation and granulocyte collection, and maintaining optimal hematocrit (5%-10%) in granulocyte collections. Because the majority of surveyed blood centers collecting stimulated granulocytes use steroids alone, modifications presented here may prove useful. Further assessment of correlation between granulocyte yield and clinical outcome will await results of additional studies.
AB - Background The past few decades have seen a resurgence of interest in leukapheresis products to improve the survival of infected patients with neutropenia. These products have a short shelf life and require donor stimulation with dexamethasone before collection. Additionally, a system with good communications and logistical support is essential. A recent survey of blood centers in North America revealed that the majority of centers collecting leukapheresis products use steroid-stimulated donors. The survey results suggested that an analysis of the process and potential process improvement would be of interest to the transfusion medicine community. Study Design and Methods Data from 2008 to 2011 regarding donor selection, donor dexamethasone stimulation, leukapheresis collection, and correlations between potentially pertinent variables for process improvement were analyzed. Results from an analysis of cost are also included. Results We evaluate 432 leukapheresis donations and demonstrate correlations between 1) pre- and poststimulation white blood cell (WBC) count (p < 0.0001), 2) interval (donor stimulation to collection) and poststimulation WBC count (p < 0.0001), and 3) poststimulation WBC count and leukapheresis product granulocyte yield (p < 0.0001). Conclusions Significant improvement in granulocyte quality and yield can be accomplished in dexamethasone-stimulated donors, by selecting eligible donors with relatively high normal prestimulation WBC counts and/or previously good responses to dexamethasone, increasing the duration between dexamethasone stimulation and granulocyte collection, and maintaining optimal hematocrit (5%-10%) in granulocyte collections. Because the majority of surveyed blood centers collecting stimulated granulocytes use steroids alone, modifications presented here may prove useful. Further assessment of correlation between granulocyte yield and clinical outcome will await results of additional studies.
UR - http://www.scopus.com/inward/record.url?scp=84885733571&partnerID=8YFLogxK
U2 - 10.1111/j.1537-2995.2012.03938.x
DO - 10.1111/j.1537-2995.2012.03938.x
M3 - Article
C2 - 23113726
AN - SCOPUS:84885733571
SN - 0041-1132
VL - 53
SP - 2123
EP - 2129
JO - Transfusion
JF - Transfusion
IS - 10
ER -