TY - JOUR
T1 - Gadolinium-enhanced 3D MRA of the aortic arch vessels the detection of atherosclerotic cerebrovascular occlusive disease
AU - Krinsky, Glenn
AU - Maya, Menahem
AU - Rofsky, Neil
AU - Lebowitz, Jonathan
AU - Nelson, Peter Kim
AU - Ambrosino, Michael
AU - Kaminer, Evan
AU - Earls, Jay
AU - Masters, Lynette
AU - Giangola, Gary
AU - Litt, Andrew
AU - Weinreb, Jeffrey
PY - 1998
Y1 - 1998
N2 - Purpose: Our goal was to evaluate non-breath-hold Gd-enhanced 3D MR angiography (MRA) for the detection of atherosclerotic occlusive disease of the aortic arch vessels and to compare image quality with two breath-hold techniques. Method: One hundred sixty consecutive patients with known or clinically suspected atherosclerotic cerebrovascular occlusive disease underwent Gd-enhanced 3D MRA of the aortic arch and great vessels. One hundred twenty-six examinations were performed with the body coil after infusion of 40 ml of Gd-DTPA; 89 of these were performed without breath- holding and 37 were acquired during suspended respiration. Thirty-four examinations were performed in a body phased-array coil with breath-holding, a timing examination, and 20 ml of contrast agent by manual (n = 17) or power (n = 17) injection. Images were evaluated for the presence of blurring and ghosting artifacts and venous enhancement. Of the 27 patients who underwent non-breath-hold MRI and digital subtraction angiography (DSA), two readers blinded to the DSA results retrospectively evaluated the MRA examinations for the presence of occlusive disease of the innominate, carotid, subclavian, and vertebral arteries. DSA correlation was not evaluated for the 71 breath-hold studies. Results: Sensitivity and specificity for arch vessel occlusive disease with non-breath-hold MRA were 38 and 94% for Reader A and 38 and 95% for Reader B. Breath-holding significantly reduced blurting and ghosting artifacts (p < 0.001) when compared with non-breath-hold imaging, and use of 20 ml of contrast medium, with a timing examination, resulted in significantly less venous enhancement than seen with 40 ml (p < 0.001). Conclusion: Non-breath-hold Gd-enhanced 3D MRA is insensitive for detecting arch vessel occlusive disease. Breath-hold imaging, in conjunction with a timing examination and a lower dose of contrast agent, improves image quality, but further studies are needed to assess diagnostic accuracy.
AB - Purpose: Our goal was to evaluate non-breath-hold Gd-enhanced 3D MR angiography (MRA) for the detection of atherosclerotic occlusive disease of the aortic arch vessels and to compare image quality with two breath-hold techniques. Method: One hundred sixty consecutive patients with known or clinically suspected atherosclerotic cerebrovascular occlusive disease underwent Gd-enhanced 3D MRA of the aortic arch and great vessels. One hundred twenty-six examinations were performed with the body coil after infusion of 40 ml of Gd-DTPA; 89 of these were performed without breath- holding and 37 were acquired during suspended respiration. Thirty-four examinations were performed in a body phased-array coil with breath-holding, a timing examination, and 20 ml of contrast agent by manual (n = 17) or power (n = 17) injection. Images were evaluated for the presence of blurring and ghosting artifacts and venous enhancement. Of the 27 patients who underwent non-breath-hold MRI and digital subtraction angiography (DSA), two readers blinded to the DSA results retrospectively evaluated the MRA examinations for the presence of occlusive disease of the innominate, carotid, subclavian, and vertebral arteries. DSA correlation was not evaluated for the 71 breath-hold studies. Results: Sensitivity and specificity for arch vessel occlusive disease with non-breath-hold MRA were 38 and 94% for Reader A and 38 and 95% for Reader B. Breath-holding significantly reduced blurting and ghosting artifacts (p < 0.001) when compared with non-breath-hold imaging, and use of 20 ml of contrast medium, with a timing examination, resulted in significantly less venous enhancement than seen with 40 ml (p < 0.001). Conclusion: Non-breath-hold Gd-enhanced 3D MRA is insensitive for detecting arch vessel occlusive disease. Breath-hold imaging, in conjunction with a timing examination and a lower dose of contrast agent, improves image quality, but further studies are needed to assess diagnostic accuracy.
KW - Atherosclerosis
KW - Blood vessels, cerebral
KW - Blood vessels, occlusion
KW - Brain, blood flow
KW - Breath-holding
KW - Magnetic resonance angiography (MRA)
KW - Magnetic resonance imaging, three-dimensional (3D MRI)
UR - http://www.scopus.com/inward/record.url?scp=0031958157&partnerID=8YFLogxK
U2 - 10.1097/00004728-199803000-00003
DO - 10.1097/00004728-199803000-00003
M3 - Article
C2 - 9530375
AN - SCOPUS:0031958157
SN - 0363-8715
VL - 22
SP - 167
EP - 178
JO - Journal of Computer Assisted Tomography
JF - Journal of Computer Assisted Tomography
IS - 2
ER -