External elastic lamina vs. luminal diameter measurement for determining stent diameter by optical coherence tomography: An ILUMIEN III substudy

Evan Shlofmitz, Allen Jeremias, Yasir Parviz, Keyvan Karimi Galougahi, Björn Redfors, Gregory Petrossian, Madison Edens, Mitsuaki Matsumura, Akiko Maehara, Gary S. Mintz, Gregg W. Stone, Richard A. Shlofmitz, Ziad A. Ali

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

Aims: Optical coherence tomography (OCT)-guided external elastic lamina (EEL)-based stent sizing is safe and as effective as intravascular ultrasound in achieving post-procedural lumen dimensions. However, when compared with automated lumen diameter (LD) measurements, this approach is time-consuming. We aimed to compare vessel diameter measurements and stent diameter selection using either of these approaches and examined whether applying a correction factor to automated LD measurements could result in selecting similar stent diameters to the EEL-based approach. Methods and results: We retrospectively compared EEL-based measurements vs. automated LD in reference segments in 154 OCT acquisitions and derived a correction factor for stent sizing using the ratio of EEL to LD measurements. We then prospectively applied the correction factor in 119 OCT acquisitions. EEL could be adequately identified in 100 acquisitions (84%) at the distal reference to allow vessel diameter measurement. Vessel diameters were larger with EEL-based vs. LD measurements at both proximal (4.12 ± 0.74 vs. 3.14 ± 0.67 mm, P < 0.0001) and distal reference segments (3.34 ± 0.75 vs. 2.64 ± 0.65 mm, P < 0.0001). EEL-based downsizing led to selection of larger stents vs. an LD-based upsizing approach (3.33 ± 0.47 vs. 2.70 ± 0.44, P < 0.0001). Application of correction factors to LD [proximal 1.32 (IQR 1.23-1.37) and distal 1.25 (IQR 1.19-1.36)] resulted in discordance in stent sizing by >0.25 mm in 63% and potentially hazardous stent oversizing in 41% of cases. Conclusion: EEL-based stent downsizing led to selection of larger stent diameters vs. LD upsizing. While applying a correction factor to automated LD measurements resulted in similar mean diameters to EEL-based measurements, this approach cannot be used clinically due to frequent and potentially hazardous stent over-sizing.

Original languageEnglish
Pages (from-to)753-759
Number of pages7
JournalEuropean Heart Journal Cardiovascular Imaging
Volume22
Issue number7
DOIs
StatePublished - 1 Jul 2021

Keywords

  • intravascular imaging
  • optical coherence tomography
  • stent sizing

Fingerprint

Dive into the research topics of 'External elastic lamina vs. luminal diameter measurement for determining stent diameter by optical coherence tomography: An ILUMIEN III substudy'. Together they form a unique fingerprint.

Cite this