TY - JOUR
T1 - Evidence-Based Consensus Guidelines Series for MicroPulse Transscleral Laser Therapy
T2 - Dosimetry and Patient Selection
AU - Grippo, Tomas M.
AU - de Crom, Ronald M.P.C.
AU - Giovingo, Michael
AU - Töteberg-Harms, Marc
AU - Francis, Brian A.
AU - Jerkins, Brian
AU - Brubaker, Jacob W.
AU - Radcliffe, Nathan
AU - An, Jella
AU - Noecker, Robert
N1 - Publisher Copyright:
© 2022 Grippo et al.
PY - 2022
Y1 - 2022
N2 - Purpose: To provide consensus-based current guidelines on optimal dosimetry and patient selection for MicroPulse Transscleral Laser Therapy (TLT) based on a review of the literature and a Delphi method. Methods: A comprehensive search of Pub Med led to the identification and analysis of 61 studies on MicroPulse TLT that contained information on laser settings and patient selection. To determine consensus in areas where there was not enough available literature, a three-round Delphi method was conducted. Results: The response rate was 90% in the first round, 90% in the second round, and 80% in the third round of the Delphi technique. Once all responses were aggregated, a live meeting was held with 80% attendance, and consensus was achieved on each of the findings detailed in this manuscript. Conclusion: Micropulse TLT is a useful addition to the glaucoma armamentarium. When used with proper surgical technique at energy settings within the boundaries described in this manuscript, MicroPulse TLT is a safe and effective treatment for many types and stages of glaucoma. Based on current knowledge and experience, the consensus recommendation of this expert panel is that the standard MicroPulse TLT settings using the revised MicroPulse P3 Probe should be 2500 mW, 31.3% duty cycle, and 4 sweeps at a sweep velocity of 20 seconds each per hemisphere. Both hemispheres avoiding the 3 and 9 clock hours should be treated. The panel also reached consensus on patient selection for MicroPulse TLT providing guidance for the use of the procedure.
AB - Purpose: To provide consensus-based current guidelines on optimal dosimetry and patient selection for MicroPulse Transscleral Laser Therapy (TLT) based on a review of the literature and a Delphi method. Methods: A comprehensive search of Pub Med led to the identification and analysis of 61 studies on MicroPulse TLT that contained information on laser settings and patient selection. To determine consensus in areas where there was not enough available literature, a three-round Delphi method was conducted. Results: The response rate was 90% in the first round, 90% in the second round, and 80% in the third round of the Delphi technique. Once all responses were aggregated, a live meeting was held with 80% attendance, and consensus was achieved on each of the findings detailed in this manuscript. Conclusion: Micropulse TLT is a useful addition to the glaucoma armamentarium. When used with proper surgical technique at energy settings within the boundaries described in this manuscript, MicroPulse TLT is a safe and effective treatment for many types and stages of glaucoma. Based on current knowledge and experience, the consensus recommendation of this expert panel is that the standard MicroPulse TLT settings using the revised MicroPulse P3 Probe should be 2500 mW, 31.3% duty cycle, and 4 sweeps at a sweep velocity of 20 seconds each per hemisphere. Both hemispheres avoiding the 3 and 9 clock hours should be treated. The panel also reached consensus on patient selection for MicroPulse TLT providing guidance for the use of the procedure.
KW - MicroPulse
KW - glaucoma
KW - transscleral laser therapy
UR - http://www.scopus.com/inward/record.url?scp=85132109273&partnerID=8YFLogxK
U2 - 10.2147/OPTH.S365647
DO - 10.2147/OPTH.S365647
M3 - Article
AN - SCOPUS:85132109273
SN - 1177-5467
VL - 16
SP - 1837
EP - 1846
JO - Clinical Ophthalmology
JF - Clinical Ophthalmology
ER -