title = "Evaluating learning curves and competence in colorectal EMR among advanced endoscopy fellows: a pilot multicenter prospective trial using cumulative sum analysis",
abstract = "Background and Aims: Data on colorectal EMR (C-EMR) training are lacking. We aimed to evaluate C-EMR training among advanced endoscopy fellows (AEFs) by using a standardized assessment tool (STAT). Methods: This multicenter prospective study used a STAT to grade AEF training in C-EMR during their 12-month fellowship. Cumulative sum analysis was used to establish learning curves and competence for cognitive and technical components of C-EMR and overall performance. Sensitivity analysis was performed by varying failure rates. AEFs completed a self-assessment questionnaire to assess their comfort level with performing C-EMR at the completion of their fellowship. Results: Six AEFs (189 C-EMRs; mean per AEF, 31.5 ± 18.5) were included. Mean polyp size was 24.3 ± 12.6 mm, and mean procedure time was 22.6 ± 16.1 minutes. Learning curve analyses revealed that less than 50% of AEFs achieved competence for key cognitive and technical C-EMR endpoints. All 6 AEFs reported feeling comfortable performing C-EMR independently at the end of their training, although only 2 of them achieved competence in their overall performance. The minimum threshold to achieve competence in these 2 AEFs was 25 C-EMRs. Conclusions: A relatively low proportion of AEFs achieved competence on key cognitive and technical aspects of C-EMR during their 12-month fellowship. The relatively low number of C-EMRs performed by AEFs may be insufficient to achieve competence, in spite of their self-reported readiness for independent practice. These pilot data serve as an initial framework for competence threshold, and suggest the need for validated tools for formal C-EMR training assessment.",
author = "{C-EMR STAT Study Group} and Dennis Yang and Perbtani, {Yaseen B.} and Yu Wang and Amir Rumman and Wang, {Andrew Y.} and Kumta, {Nikhil A.} and DiMaio, {Christopher J.} and Andrew Antony and Trindade, {Arvind J.} and Rolston, {Vineet S.} and D'Souza, {Lionel S.} and {Corral Hurtado}, {Juan E.} and Victoria Gomez and Heiko Pohl and Draganov, {Peter V.} and Beyth, {Rebecca J.} and Lee, {Ji Hyun} and Antonio Cheesman and Uppal, {Dushant S.} and Sejpal, {Divyesh V.} and Bucobo, {Juan C.} and Wallace, {Michael B.} and Saowanee Ngamruengphong and Olumide Ajayeoba and Khara, {Harshit S.} and Diehl, {David L.} and Salmaan Jawaid and Forsmark, {Christopher E.}",
note = "Funding Information: DISCLOSURE: The following authors disclosed financial relationships: D. Yang: Consultant for Boston Scientific, Lumendi, and Steris Endoscopy. V. Gomez: Consultant for Olympus America. N.A. Kumta: Consultant for Apollo Endosurgery, Boston Scientific, Gyrus ACMI Inc, GLG consulting, and Olympus. C.J. DiMaio: Consultant and teacher for Boston Scientific and Medtronic; speaker for AbbVie. A.J. Trindade: Consultant for Pentax Medical and Olympus America; research support from Ninepoint Medical. H. Pohl: Research support from Steris and Cosmo/Aries Pharmaceuticals. P.V. Draganov: Consultant for Boston Scientific, Olympus America, Cook Medical, Microtech, Steris Endoscopy, Merit, Lumendi, and Fujifilm. J.C. Bucobo: Consultant for Cook Medical. M.B. Wallace: Consultant for Virgo Inc, Cosmo/Aries Pharmaceuticals, Anx Robotica, Covidien , GI Supply, Endokey, Endostart, Microtech, and Boston Scientific; stock options with Virgo Inc; and research support from Fujifilm , Boston Scientific, Olympus America, Medtronic, Ninepoint Medical, and Cosmo/Aries Pharmaceuticals. S Ngamruenphong: Consultant for Boston Scientific. H.S. Khara: Consultant for Olympus America, Boston Scientific, Medtronic, Pentax, and Steris Endoscopy. D.L. Diehl: Consultant for Boston Scientific, Cook Medical, Olympus America, Pentax, GI Supply, Microtech, Merit Endo Tek, Cernostics, and Lumendi. All other authors disclosed no financial relationships. Research support for this study was provided by internal funding from the Department of Medicine at the University of Florida. Funding Information: DISCLOSURE: The following authors disclosed financial relationships: D. Yang: Consultant for Boston Scientific, Lumendi, and Steris Endoscopy. V. Gomez: Consultant for Olympus America. N.A. Kumta: Consultant for Apollo Endosurgery, Boston Scientific, Gyrus ACMI Inc, GLG consulting, and Olympus. C.J. DiMaio: Consultant and teacher for Boston Scientific and Medtronic; speaker for AbbVie. A.J. Trindade: Consultant for Pentax Medical and Olympus America; research support from Ninepoint Medical. H. Pohl: Research support from Steris and Cosmo/Aries Pharmaceuticals. P.V. Draganov: Consultant for Boston Scientific, Olympus America, Cook Medical, Microtech, Steris Endoscopy, Merit, Lumendi, and Fujifilm. J.C. Bucobo: Consultant for Cook Medical. M.B. Wallace: Consultant for Virgo Inc, Cosmo/Aries Pharmaceuticals, Anx Robotica, Covidien, GI Supply, Endokey, Endostart, Microtech, and Boston Scientific; stock options with Virgo Inc; and research support from Fujifilm, Boston Scientific, Olympus America, Medtronic, Ninepoint Medical, and Cosmo/Aries Pharmaceuticals. S Ngamruenphong: Consultant for Boston Scientific. H.S. Khara: Consultant for Olympus America, Boston Scientific, Medtronic, Pentax, and Steris Endoscopy. D.L. Diehl: Consultant for Boston Scientific, Cook Medical, Olympus America, Pentax, GI Supply, Microtech, Merit Endo Tek, Cernostics, and Lumendi. All other authors disclosed no financial relationships. Research support for this study was provided by internal funding from the Department of Medicine at the University of Florida. Publisher Copyright: {\textcopyright} 2021",
year = "2021",
month = mar,
doi = "10.1016/j.gie.2020.09.023",
language = "English",
volume = "93",
pages = "682--690.e4",
journal = "Gastrointestinal Endoscopy",
issn = "0016-5107",
publisher = "Mosby Inc.",
number = "3",
}