TY - JOUR
T1 - Erratum to
T2 - Tracking and Reducing SF6 Usage in Radiation Oncology: A Step Toward Net-Zero Health Care Emissions Lichter KE, Bloom JR, Sheu RD, et al. Pract Radiat Oncol. 2023 Nov-Dec;13(6): e471-e474 (Practical Radiation Oncology (2023) 13(6) (e471–e474), (S1879850023001741), (10.1016/j.prro.2023.06.003))
AU - Lichter, Katie E.
AU - Bloom, Julie R.
AU - Sheu, Ren Dih
AU - Zalavari, Laszlo Tibor
AU - Leung, Kayla
AU - Collins, Amy
AU - Witztum, Alon
AU - Chuter, Robert
N1 - Publisher Copyright:
© 2025 American Society for Radiation Oncology
PY - 2025/3/1
Y1 - 2025/3/1
N2 - The authors would like to highlight the following corrections (Abstract): "It is estimated that the approximate 15,042 LINACs globally may leak up to 64,884,185.9 CO2-eq/year, which is the equivalent greenhouse gas emissions of 13,981 gasoline-powered passenger vehicles driven for one year." (Main text) "The Christie, a cancer center in the United Kingdom calculated an average leakage of SF6 from their LINACs to be 0.0005 kg/day, or 0.1835 kg/year. Using data from International Atomic Energy Agency's DIrectory of RAdiotherapy Centres (DIRAC)3, multiplied by the 23,507 kg CO2 equivalent (CO2-eq) conversion factor, it is estimated that the 15,042 LINACs globally may leak up to 64,884,185.9 CO2-eq/year. This is the equivalent greenhouse gas emissions of 13,981 gasoline-powered passenger vehicles driven for one year." This should be revised to: (Abstract): "It is estimated that approximately 15,042 LINACs worldwide, in total, may leak up to 21,209,220 kg CO₂-eq per year, equivalent to the greenhouse gas emissions of 4,947 gasoline-powered or 18,731 electric-powered passenger vehicles driven for one year." (Main text) "The Christie, a cancer center in the United Kingdom, calculated an average leakage of SF6 from their LINACs to be 0.06 kg/year. Using data from International Atomic Energy Agency's DIrectory of RAdiotherapy Centres (DIRAC)3 and applying a CO₂-equivalent (CO₂-eq) conversion factor of 23,507 kg per kg of SF6, it is estimated that 15,042 LINACs worldwide may leak up to 21,209,220 kg CO₂-eq per year. This is equivalent to the greenhouse gas emissions of 4,947 gasoline-powered or 18,731 electric-powered passenger vehicles driven for one year."
AB - The authors would like to highlight the following corrections (Abstract): "It is estimated that the approximate 15,042 LINACs globally may leak up to 64,884,185.9 CO2-eq/year, which is the equivalent greenhouse gas emissions of 13,981 gasoline-powered passenger vehicles driven for one year." (Main text) "The Christie, a cancer center in the United Kingdom calculated an average leakage of SF6 from their LINACs to be 0.0005 kg/day, or 0.1835 kg/year. Using data from International Atomic Energy Agency's DIrectory of RAdiotherapy Centres (DIRAC)3, multiplied by the 23,507 kg CO2 equivalent (CO2-eq) conversion factor, it is estimated that the 15,042 LINACs globally may leak up to 64,884,185.9 CO2-eq/year. This is the equivalent greenhouse gas emissions of 13,981 gasoline-powered passenger vehicles driven for one year." This should be revised to: (Abstract): "It is estimated that approximately 15,042 LINACs worldwide, in total, may leak up to 21,209,220 kg CO₂-eq per year, equivalent to the greenhouse gas emissions of 4,947 gasoline-powered or 18,731 electric-powered passenger vehicles driven for one year." (Main text) "The Christie, a cancer center in the United Kingdom, calculated an average leakage of SF6 from their LINACs to be 0.06 kg/year. Using data from International Atomic Energy Agency's DIrectory of RAdiotherapy Centres (DIRAC)3 and applying a CO₂-equivalent (CO₂-eq) conversion factor of 23,507 kg per kg of SF6, it is estimated that 15,042 LINACs worldwide may leak up to 21,209,220 kg CO₂-eq per year. This is equivalent to the greenhouse gas emissions of 4,947 gasoline-powered or 18,731 electric-powered passenger vehicles driven for one year."
UR - https://www.scopus.com/pages/publications/105000024251
U2 - 10.1016/j.prro.2025.01.003
DO - 10.1016/j.prro.2025.01.003
M3 - Comment/debate
C2 - 40155185
AN - SCOPUS:105000024251
SN - 1879-8500
VL - 15
SP - 216
JO - Practical Radiation Oncology
JF - Practical Radiation Oncology
IS - 2
ER -