Skip to main navigation Skip to search Skip to main content

Electroretinogram monitoring of dose-dependent toxicity after ophthalmic artery chemosurgery in retinoblastoma eyes: Six year review

  • Jasmine H. Francis
  • , David H. Abramson
  • , Y. Pierre Gobin
  • , Brian P. Marr
  • , Ira J. Dunkel
  • , Elyn R. Riedel
  • , Scott E. Brodie

Research output: Contribution to journalReview articlepeer-review

45 Scopus citations

Abstract

Purpose: To report electroretinogram responses of retinoblastoma children under anesthesia before and after treatment with chemotherapeutic drugs (melphalan, topotecan, carboplatin) delivery by ophthalmic artery chemosurgery (OAC). Methods: A cohort study of 81 patients with retinoblastoma treated with OAC. All patients treated with OAC at our center through May 2012 for whom the requisite ERG data were available are included in the analysis. This study recorded the ERG 30 Hz flicker amplitude response changes from baseline, at 3 and 12 months following OAC treatment completion. Both univariate and multivariate linear regression models were evaluated, with generalized estimating equations to correct for correlations within patients. Independent numerical variables included maximum doses and cumulative doses of melphalan, topotecan and carboplatin. Results: By univariate analysis, both melphalan and topotecan appear to be associated with changes in ERG amplitude at both 3 and 12 months; but for the most part, these changes are minimal and likely clinically insignificant. By multivariate analysis, maximum and cumulative melphalan have a modest, temporary effect on the ERG amplitude change, which is apparent at 3 months but no longer evident at 12 months after completing treatment. By multivariate analysis, topotecan and carboplatin do not appear to adversely effect the change in ERG response. Conclusion: Melphalan has the strongest, and carboplatin the weakest association with reduction in ERG response amplitudes; but for the most part, these changes are minimal and likely clinically insignificant. These conclusions apply only over the dose ranges used here, and should be applied with caution.

Original languageEnglish
Article numbere84247
JournalPLoS ONE
Volume9
Issue number1
DOIs
StatePublished - 20 Jan 2014

Fingerprint

Dive into the research topics of 'Electroretinogram monitoring of dose-dependent toxicity after ophthalmic artery chemosurgery in retinoblastoma eyes: Six year review'. Together they form a unique fingerprint.

Cite this