Efficacy and safety of novel temperature-controlled radiofrequency ablation system during pulmonary vein isolation in patients with paroxysmal atrial fibrillation: TRAC-AF study

Zdenek Starek, Frantisek Lehar, Jiri Jez, Martin Pesl, Petr Neuzil, Lucie Sediva, Jan Petru, Libor Dujka, Moritoshi Funasako, Josef Kautzner, Petr Peichl, Bashar Aldhoon, Jean Paul Albenque, Stephane Combes, Serge Boveda, Srinivas R. Dukkipati, Vivek Y. Reddy

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Background and purpose: Saline-irrigated radiofrequency ablation (RFA) for atrial fibrillation (AF) is limited by the absence of reliable thermal feedback limiting the utility of temperature monitoring for power titration. The DiamondTemp (DT) ablation catheter was designed to allow efficient temperature-controlled irrigated ablation. We sought to assess the 1-year clinical safety and efficacy of the DT catheter in treating drug-refractory paroxysmal AF. Methods: The TRAC-AF trial (NCT02821351) is a prospective, multi-center (n = 4), single-arm study which enrolled patients with symptomatic, drug-refractory, paroxysmal AF. Using the DT catheter, point-by-point ablation was performed around all pulmonary veins (PVs) to achieve PV isolation (PVI). Ablation was performed in a temperature-controlled mode (60 °C, max 50 W). Acute and chronic efficacy and safety was evaluated. Results: Seventy-one patients (age 69.9 ± 11.0 years; 60.6% male) were ablated using the DT catheter. The mean fluoroscopy and RF ablation times were 9.3 ± 6.1 min and 20.6 ± 8.9 min, respectively. Acute isolation of all PVs was achieved in 100% of patients, and freedom from AF after 1 year was 70.6%. There were no steam pops, char, or coagulum on the catheter tip after ablation. There were few serious procedure/device-related adverse events including a single case of cardiac tamponade (1.4%) and transient ischemic attack (1.4). Conclusion: This first in man series demonstrates that temperature-controlled irrigated RFA with the DT catheter is efficient, safe, and effective in the treatment of paroxysmal AF. Randomized controlled trials are ongoing and will evaluate better the role of this catheter in relation to standard RFA. Trial registration: Registered on the site ClinicalTrials.gov

Original languageEnglish
Pages (from-to)375-381
Number of pages7
JournalJournal of Interventional Cardiac Electrophysiology
Volume64
Issue number2
DOIs
StatePublished - Aug 2022

Keywords

  • Atrial fibrillation
  • Catheter radiofrequency ablation
  • Diamond tip irrigated catheter
  • High-resolution electrograms
  • Safety and efficacy
  • Temperature contol ablation

Fingerprint

Dive into the research topics of 'Efficacy and safety of novel temperature-controlled radiofrequency ablation system during pulmonary vein isolation in patients with paroxysmal atrial fibrillation: TRAC-AF study'. Together they form a unique fingerprint.

Cite this