TY - JOUR
T1 - Efficacy and safety of novel temperature-controlled radiofrequency ablation system during pulmonary vein isolation in patients with paroxysmal atrial fibrillation
T2 - TRAC-AF study
AU - Starek, Zdenek
AU - Lehar, Frantisek
AU - Jez, Jiri
AU - Pesl, Martin
AU - Neuzil, Petr
AU - Sediva, Lucie
AU - Petru, Jan
AU - Dujka, Libor
AU - Funasako, Moritoshi
AU - Kautzner, Josef
AU - Peichl, Petr
AU - Aldhoon, Bashar
AU - Albenque, Jean Paul
AU - Combes, Stephane
AU - Boveda, Serge
AU - Dukkipati, Srinivas R.
AU - Reddy, Vivek Y.
N1 - Publisher Copyright:
© 2021, Springer Science+Business Media, LLC, part of Springer Nature.
PY - 2022/8
Y1 - 2022/8
N2 - Background and purpose: Saline-irrigated radiofrequency ablation (RFA) for atrial fibrillation (AF) is limited by the absence of reliable thermal feedback limiting the utility of temperature monitoring for power titration. The DiamondTemp (DT) ablation catheter was designed to allow efficient temperature-controlled irrigated ablation. We sought to assess the 1-year clinical safety and efficacy of the DT catheter in treating drug-refractory paroxysmal AF. Methods: The TRAC-AF trial (NCT02821351) is a prospective, multi-center (n = 4), single-arm study which enrolled patients with symptomatic, drug-refractory, paroxysmal AF. Using the DT catheter, point-by-point ablation was performed around all pulmonary veins (PVs) to achieve PV isolation (PVI). Ablation was performed in a temperature-controlled mode (60 °C, max 50 W). Acute and chronic efficacy and safety was evaluated. Results: Seventy-one patients (age 69.9 ± 11.0 years; 60.6% male) were ablated using the DT catheter. The mean fluoroscopy and RF ablation times were 9.3 ± 6.1 min and 20.6 ± 8.9 min, respectively. Acute isolation of all PVs was achieved in 100% of patients, and freedom from AF after 1 year was 70.6%. There were no steam pops, char, or coagulum on the catheter tip after ablation. There were few serious procedure/device-related adverse events including a single case of cardiac tamponade (1.4%) and transient ischemic attack (1.4). Conclusion: This first in man series demonstrates that temperature-controlled irrigated RFA with the DT catheter is efficient, safe, and effective in the treatment of paroxysmal AF. Randomized controlled trials are ongoing and will evaluate better the role of this catheter in relation to standard RFA. Trial registration: Registered on the site ClinicalTrials.gov
AB - Background and purpose: Saline-irrigated radiofrequency ablation (RFA) for atrial fibrillation (AF) is limited by the absence of reliable thermal feedback limiting the utility of temperature monitoring for power titration. The DiamondTemp (DT) ablation catheter was designed to allow efficient temperature-controlled irrigated ablation. We sought to assess the 1-year clinical safety and efficacy of the DT catheter in treating drug-refractory paroxysmal AF. Methods: The TRAC-AF trial (NCT02821351) is a prospective, multi-center (n = 4), single-arm study which enrolled patients with symptomatic, drug-refractory, paroxysmal AF. Using the DT catheter, point-by-point ablation was performed around all pulmonary veins (PVs) to achieve PV isolation (PVI). Ablation was performed in a temperature-controlled mode (60 °C, max 50 W). Acute and chronic efficacy and safety was evaluated. Results: Seventy-one patients (age 69.9 ± 11.0 years; 60.6% male) were ablated using the DT catheter. The mean fluoroscopy and RF ablation times were 9.3 ± 6.1 min and 20.6 ± 8.9 min, respectively. Acute isolation of all PVs was achieved in 100% of patients, and freedom from AF after 1 year was 70.6%. There were no steam pops, char, or coagulum on the catheter tip after ablation. There were few serious procedure/device-related adverse events including a single case of cardiac tamponade (1.4%) and transient ischemic attack (1.4). Conclusion: This first in man series demonstrates that temperature-controlled irrigated RFA with the DT catheter is efficient, safe, and effective in the treatment of paroxysmal AF. Randomized controlled trials are ongoing and will evaluate better the role of this catheter in relation to standard RFA. Trial registration: Registered on the site ClinicalTrials.gov
KW - Atrial fibrillation
KW - Catheter radiofrequency ablation
KW - Diamond tip irrigated catheter
KW - High-resolution electrograms
KW - Safety and efficacy
KW - Temperature contol ablation
UR - http://www.scopus.com/inward/record.url?scp=85107480724&partnerID=8YFLogxK
U2 - 10.1007/s10840-021-00986-0
DO - 10.1007/s10840-021-00986-0
M3 - Article
AN - SCOPUS:85107480724
SN - 1383-875X
VL - 64
SP - 375
EP - 381
JO - Journal of Interventional Cardiac Electrophysiology
JF - Journal of Interventional Cardiac Electrophysiology
IS - 2
ER -