TY - JOUR
T1 - Effect of padding duration on radiation dose and image interpretation in prospectively ECG-Triggered coronary CT angiography
AU - LaBounty, Troy M.
AU - Leipsic, Jonathon
AU - Min, James K.
AU - Heilbron, Brett
AU - John Mancini, G. B.
AU - Lin, Fay Y.
AU - Earls, James P.
PY - 2010/4
Y1 - 2010/4
N2 - OBJECTIVE. Prospectively ECG-triggered coronary CT angiography images are acquired during a window in middiastole. Additional surrounding x-ray beam on time, or padding, can be variably set, and the increased padding results in additional available phases for analysis. The purpose of this study was to assess the effect of padding duration on image interpretability and its incident effect on radiation dose. SUBJECTS AND METHODS. We prospectively evaluated imaging of 886 patients undergoing consecutive prospectively ECG-triggered coronary CT angiographic examinations at three centers and compared the findings in patients stratified by padding duration. We assessed the effect of padding duration on image interpretability and radiation dose. RESULTS. The mean patient age was 56 ± 12 years, and 58% of the patients were men. The median heart rate was 55 beats/min (interquartile range, 50-61 beats/min). Padding duration was 0, 1-99, and 100-150 milliseconds for 268, 482, and 136 patients, respectively, with no difference in image interpretability rate between groups (per patient, 98.8%, 97.3%, and 97.1%; per artery, 99.2%, 99.2%, and 99.1%). The groups differed in median radiation dose (2.3 mSv [interquartile range, 1.5-3.2 mSv]; 3.8 mSv [interquartile range, 2.3-4.7 mSv]; 5.5 mSv [interquartile range, 3.8-6.1 mSv]; p < 0.001). Independent of patient and scan parameters, increased padding was associated with greater radiation dose (45% increase per 100-millisecond increase in padding, p < 0.001). CONCLUSION. In a large multicenter study of coronary CT angiography of patients with excellent heart rate control, the use of minimal padding was associated with a substantial reduction in radiation dose with preserved image interpretability. Use of no or reduced padding should be considered in dose-reduction strategies.
AB - OBJECTIVE. Prospectively ECG-triggered coronary CT angiography images are acquired during a window in middiastole. Additional surrounding x-ray beam on time, or padding, can be variably set, and the increased padding results in additional available phases for analysis. The purpose of this study was to assess the effect of padding duration on image interpretability and its incident effect on radiation dose. SUBJECTS AND METHODS. We prospectively evaluated imaging of 886 patients undergoing consecutive prospectively ECG-triggered coronary CT angiographic examinations at three centers and compared the findings in patients stratified by padding duration. We assessed the effect of padding duration on image interpretability and radiation dose. RESULTS. The mean patient age was 56 ± 12 years, and 58% of the patients were men. The median heart rate was 55 beats/min (interquartile range, 50-61 beats/min). Padding duration was 0, 1-99, and 100-150 milliseconds for 268, 482, and 136 patients, respectively, with no difference in image interpretability rate between groups (per patient, 98.8%, 97.3%, and 97.1%; per artery, 99.2%, 99.2%, and 99.1%). The groups differed in median radiation dose (2.3 mSv [interquartile range, 1.5-3.2 mSv]; 3.8 mSv [interquartile range, 2.3-4.7 mSv]; 5.5 mSv [interquartile range, 3.8-6.1 mSv]; p < 0.001). Independent of patient and scan parameters, increased padding was associated with greater radiation dose (45% increase per 100-millisecond increase in padding, p < 0.001). CONCLUSION. In a large multicenter study of coronary CT angiography of patients with excellent heart rate control, the use of minimal padding was associated with a substantial reduction in radiation dose with preserved image interpretability. Use of no or reduced padding should be considered in dose-reduction strategies.
KW - CT
KW - Coronary angiography
KW - Radiation dose tomograph
UR - http://www.scopus.com/inward/record.url?scp=77950618805&partnerID=8YFLogxK
U2 - 10.2214/AJR.09.3371
DO - 10.2214/AJR.09.3371
M3 - Article
C2 - 20308494
AN - SCOPUS:77950618805
SN - 0361-803X
VL - 194
SP - 933
EP - 937
JO - American Journal of Roentgenology
JF - American Journal of Roentgenology
IS - 4
ER -