N2 - Sutureless/rapid-deployment (SURD) valves are options different from the stented prostheses included in the pivotal trials comparing surgical aortic valve replacement (AVR) and transcatheter aortic valve implantation (TAVI). We performed a meta-analysis with reconstructed time-to-event data of matched studies published by November 2021 to compare SURD-AVR and TAVI. Primary endpoints were 30-day mortality and overall survival in the follow-up. Secondary endpoints included: 30-day stroke, acute kidney injury (AKI), major bleeding, permanent pacemaker implantation (PPI), paravalvular leak (PVL), prosthesis-patient mismatch (PPM), postoperative aortic valve area (AVA), and mean gradients. Ten studies met our eligibility criteria, including a total of 5134 patients (2567 underwent SURD-AVR and 2567 underwent TAVI). Pooled risk of 30-day mortality did not favor any group (odds ratio [OR]: 0.69; 95% confidence interval [CI]: 0.31–1.53; p = 0.360). Patients undergoing SURD-AVR had lower risk of PVL (OR: 0.09; 95% CI: 0.05–0.17; p < 0.001). No statistically significant differences were observed for 30-day stroke, AKI, major bleeding, PPI, PPM, and postoperative AVA. In the follow-up, we observed a higher risk of mortality (hazard ratio: 1.74; 95% CI: 1.26–2.40; p < 0.001) with TAVI. Patients who underwent SURD-AVR experienced better survival, however, the interpretation of these results warrant caution due to the fact that SURD-AVR patients tended to be younger than TAVI patients. Structural heart surgeons and interventional cardiologists should consider initial risk and life expectancy when referring patients for one approach over the other.
AB - Sutureless/rapid-deployment (SURD) valves are options different from the stented prostheses included in the pivotal trials comparing surgical aortic valve replacement (AVR) and transcatheter aortic valve implantation (TAVI). We performed a meta-analysis with reconstructed time-to-event data of matched studies published by November 2021 to compare SURD-AVR and TAVI. Primary endpoints were 30-day mortality and overall survival in the follow-up. Secondary endpoints included: 30-day stroke, acute kidney injury (AKI), major bleeding, permanent pacemaker implantation (PPI), paravalvular leak (PVL), prosthesis-patient mismatch (PPM), postoperative aortic valve area (AVA), and mean gradients. Ten studies met our eligibility criteria, including a total of 5134 patients (2567 underwent SURD-AVR and 2567 underwent TAVI). Pooled risk of 30-day mortality did not favor any group (odds ratio [OR]: 0.69; 95% confidence interval [CI]: 0.31–1.53; p = 0.360). Patients undergoing SURD-AVR had lower risk of PVL (OR: 0.09; 95% CI: 0.05–0.17; p < 0.001). No statistically significant differences were observed for 30-day stroke, AKI, major bleeding, PPI, PPM, and postoperative AVA. In the follow-up, we observed a higher risk of mortality (hazard ratio: 1.74; 95% CI: 1.26–2.40; p < 0.001) with TAVI. Patients who underwent SURD-AVR experienced better survival, however, the interpretation of these results warrant caution due to the fact that SURD-AVR patients tended to be younger than TAVI patients. Structural heart surgeons and interventional cardiologists should consider initial risk and life expectancy when referring patients for one approach over the other.
KW - cardiac surgical procedures
KW - cardiovascular surgical procedures
KW - meta-analysis
KW - transcatheter aortic valve replacement
UR - http://www.scopus.com/inward/record.url?scp=85130631173&partnerID=8YFLogxK
U2 - 10.1002/ccd.30162
DO - 10.1002/ccd.30162
M3 - Article
C2 - 35312216
AN - SCOPUS:85130631173
SN - 1522-1946
VL - 99
SP - 1886
EP - 1896
JO - Catheterization and Cardiovascular Interventions
JF - Catheterization and Cardiovascular Interventions
IS - 6
ER -