Skip to main navigation Skip to search Skip to main content

Dosimetric differences between cesium-131 and iodine-125 brachytherapy for the treatment of resected brain metastases

  • Menachem Z. Yondorf
  • , Shahdabul Faraz
  • , Andrew W. Smith
  • , Albert Sabbas
  • , Bhupesh Parashar
  • , Theodore H. Schwartz
  • , A. Gabriella Wernicke

Research output: Contribution to journal › Article › peer-review

16 Scopus citations

Abstract

Purpose: To compare treatment plans and evaluate dosimetric characteristics of permanent cesium-131 (131Cs) vs. iodine-125 (125I) implants used in brain brachytherapy. Material and methods: Twenty-four patients with 131Cs implants from a prospective phase I/II trial were re-planned with 125I implants. In order to evaluate the volume of brain tissue exposed to radiation therapy (RT), the dose volume histogram was generated for both radioisotopes. To evaluate the dosimetric differences of the two radioisotopes we compared homogeneity (HI) and conformity indices (CI), and dose covering 100% (D100), 90% (D90), 80% (D80), and 50% (D50) of the clinical target volume (CTV). Results: At the 100%, 90%, 80%, and 50% isodose lines, the 131Cs plans exposed less mean volume of brain tissue than the 125I plans (p < 0.001). The D100, D90, D80, and D50 were smaller for 131Cs (p < 0.001). The HI and CI for 131Cs vs. 125I were 19.71 vs. 29.04 and 1.31 vs. 1.92, respectively (p < 0.001). Conclusions: Compared to 125I, 131Cs exposed smaller volumes of brain tissue to equivalent doses of radiation and delivered lower radiation doses to equivalent volumes of the CTV. 131Cs exhibited a higher HI, indicating increased uniformity of doses within the CTV. Lastly, 131Cs presented a CI closer to 1, indicating that the total volume receiving the prescription dose was closer to the desired CTV volume. These results suggest that 131Cs is dosimetrically superior to 125I and may explain the reason for the 0% incidence of radiation necrosis (RN) in our previously published prospective study using 131Cs.

Original languageEnglish
Pages (from-to)311-316
Number of pages6
JournalJournal of Contemporary Brachytherapy
Volume12
Issue number4
DOIs
StatePublished - 2020
Externally publishedYes

Keywords

  • Brachytherapy
  • Cesium-131 (Cs)
  • Iodine-125 (I)
  • Metastases
  • Radiation necrosis
  • Recurrence

Fingerprint

Dive into the research topics of 'Dosimetric differences between cesium-131 and iodine-125 brachytherapy for the treatment of resected brain metastases'. Together they form a unique fingerprint.

Cite this