T1 - Diffusion-weighted imaging of the abdomen at 3.0 Tesla
T2 - Image quality and apparent diffusion coefficient reproducibility compared with 1.5 Tesla
AU - Rosenkrantz, Andrew B.
AU - Oei, Marcel
AU - Babb, James S.
AU - Niver, Benjamin E.
AU - Taouli, Bachir
PY - 2011/1
Y1 - 2011/1
N2 - Purpose To compare single-shot echo-planar imaging (SS EPI) diffusion-weighted MRI (DWI) of abdominal organs between 1.5 Tesla (T) and 3.0T in healthy volunteers in terms of image quality, apparent diffusion coefficient (ADC) values, and ADC reproducibility. Materials and Methods Eight healthy volunteers were prospectively imaged in this HIPAA-compliant IRB-approved study. Each subject underwent two consecutive scans at both 1.5 and 3.0T, which included breathhold and free-breathing DWI using a wide range of b-values (0 to 800 s/mm2). A blinded observer rated subjective image quality (maximum score= 8), and a separate observer placed regions of interest within the liver, renal cortices, pancreas, and spleen to measure ADC at each field strength. Paired Wilcoxon tests were used to compare abdominal DWI between 1.5T and 3.0T for specific combinations of organs, b-values, and acquisition techniques. Results Subjective image quality was significantly lower at 3.0T for all comparisons (P = 0.0078- 0.0156). ADC values were similar at 1.5T and 3.0T for all assessed organs, except for lower liver ADC at 3.0T using b0-500-600 and breathhold technique. ADC reproducibility was moderate at both 1.5T and 3.0T, with no significant difference in coefficient of variation of ADC between field strengths. Conclusion Compared with 1.5T, SS EPI at 3.0T provided generally similar ADC values, however, with worse image quality. Further optimization of abdominal DWI at 3.0T is needed.
AB - Purpose To compare single-shot echo-planar imaging (SS EPI) diffusion-weighted MRI (DWI) of abdominal organs between 1.5 Tesla (T) and 3.0T in healthy volunteers in terms of image quality, apparent diffusion coefficient (ADC) values, and ADC reproducibility. Materials and Methods Eight healthy volunteers were prospectively imaged in this HIPAA-compliant IRB-approved study. Each subject underwent two consecutive scans at both 1.5 and 3.0T, which included breathhold and free-breathing DWI using a wide range of b-values (0 to 800 s/mm2). A blinded observer rated subjective image quality (maximum score= 8), and a separate observer placed regions of interest within the liver, renal cortices, pancreas, and spleen to measure ADC at each field strength. Paired Wilcoxon tests were used to compare abdominal DWI between 1.5T and 3.0T for specific combinations of organs, b-values, and acquisition techniques. Results Subjective image quality was significantly lower at 3.0T for all comparisons (P = 0.0078- 0.0156). ADC values were similar at 1.5T and 3.0T for all assessed organs, except for lower liver ADC at 3.0T using b0-500-600 and breathhold technique. ADC reproducibility was moderate at both 1.5T and 3.0T, with no significant difference in coefficient of variation of ADC between field strengths. Conclusion Compared with 1.5T, SS EPI at 3.0T provided generally similar ADC values, however, with worse image quality. Further optimization of abdominal DWI at 3.0T is needed.
KW - ADC reproducibility
KW - abdomen
KW - apparent diffusion coefficient
KW - diffusion-weighted imaging
KW - liver
UR - http://www.scopus.com/inward/record.url?scp=78650642355&partnerID=8YFLogxK
U2 - 10.1002/jmri.22395
DO - 10.1002/jmri.22395
M3 - Article
C2 - 21182130
AN - SCOPUS:78650642355
SN - 1053-1807
VL - 33
SP - 128
EP - 135
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 1
ER -