Objectives: The current study aimed at determining the best cutoff value of angiographic and intravascular ultrasound (IVUS) parameters for defining fractional flow reserve (FFR) b0.8 in patients with single coronary artery lesion. Background: The correlation between angiographic or IVUS variables and FFR in patients with single coronary artery lesions has not been studied yet. Methods: Quantitative coronary analysis and IVUS and FFR measurements were used in 323 patients with a single lesion. The best angiographic and IVUS cutoff values and their predictive value for FFRb0.8 were compared using area under the receiver-operator characteristic curve (AUC). Results: FFRb0.8 was in 54.2%. Minimal lumen area (MLA), plaque burden (PB), lesion length (LL) and lesion at left anterior descending artery (LAD) were four predictors of FFRb0.8. LL had less value in predicting FFRb0.8. The cutoff values of PB and MLA for FFRb0.8 were 72.7% and 2.97 mm2.MLA and PB had similar high diagnostic value for vessel size≥3 mm(cutoff values: 3.02 mm2 and 80.7%), proximal LAD lesion (cutoff values: 3.04 mm2 and 76.5%) and unstable angina (2.82 mm2 and 71.9%). Combination of MLA (2.82 mm2) and PB (80.6%) had increased diagnostic value for distal LAD lesion. Only PB (71%) had higher diagnostic value for diabetic patients. MLA and PB could not predict FFRb0.8 for vessel sizeb3 mm, and non-LAD lesion. Conclusion: Best cutoff value ofMLA and PB for FFRb0.8 in patientswith a single lesion is patient-, vessel size- and lesion location-oriented. PB has strengthened diagnostic accuracy for diabetic patients.

Original languageEnglish
Pages (from-to)1364-1369
Number of pages6
JournalInternational Journal of Cardiology
Volume168
Issue number2
DOIs
StatePublished - 30 Sep 2013
Externally publishedYes

Keywords

  • Diagnostic value
  • Fractional flow reserve
  • Intravascular ultrasound
  • Quantitative coronary analysis
  • Receiver operator curve

Fingerprint

Dive into the research topics of 'Diagnostic accuracy of quantitative angiographic and intravascular ultrasound parameters predicting the functional significance of single de novo lesions'. Together they form a unique fingerprint.

Cite this