Skip to main navigation Skip to search Skip to main content

Design and evaluation of a transesophageal HIFU probe for ultrasound-guided cardiac ablation: Simulation of a HIFU mini-maze procedure and preliminary ex vivo trials

  • Elodie Constanciel
  • , W. Apoutou N'Djin
  • , Francis Bessière
  • , Françoise Chavrier
  • , Daniel Grinberg
  • , Alexandre Vignot
  • , Philippe Chevalier
  • , Jean Yves Chapelon
  • , Cyril Lafon

Research output: Contribution to journal › Article › peer-review

34 Scopus citations

Abstract

Atrial fibrillation (AF) is the most frequent cardiac arrhythmia. Left atrial catheter ablation is currently performed to treat this disease. Several energy sources are used, such as radio-frequency or cryotherapy. The main target of this procedure is to isolate the pulmonary veins. However, significant complications caused by the invasive procedure are described, such as stroke, tamponade, and atrioesophageal fistula, and a second intervention is often needed to avoid atrial fibrillation recurrence. For these reasons, a minimally-invasive device allowing performance of more complex treatments is still needed. High-intensity focused ultrasound (HIFU) can cause deep tissue lesions without damaging intervening tissues. Left atrial ultrasound-guided transesophageal HIFU ablation could have the potential to become a new ablation technique. The goal of this study was to design and test a minimally-invasive ultrasound-guided transesophageal HIFU probe under realistic treatment conditions. First, numerical simulations were conducted to determine the probe geometry, and to validate the feasibility of performing an AF treatment using a HIFU mini-maze (HIFUMM) procedure. Then, a prototype was manufactured and characterized. The 18-mm-diameter probe head housing contained a 3-MHz spherical truncated HIFU transducer divided into 8 rings, with a 5-MHz commercial transesophageal echocardiography (TEE) transducer integrated in the center. Finally, ex vivo experiments were performed to test the impact of the esophagus layer between the probe and the tissue to treat, and also the influence of the lungs and the vascularization on lesion formation. First results show that this prototype successfully created ex vivo transmural myocardial lesions under ultrasound guidance, while preserving intervening tissues (such as the esophagus). Ultrasound-guided transesophageal HIFU can be a good candidate for treatment of AF in the future.

Original languageEnglish
Article number6587396
Pages (from-to)1868-1883
Number of pages16
JournalIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Volume60
Issue number9
DOIs
StatePublished - 2013
Externally publishedYes

Fingerprint

Dive into the research topics of 'Design and evaluation of a transesophageal HIFU probe for ultrasound-guided cardiac ablation: Simulation of a HIFU mini-maze procedure and preliminary ex vivo trials'. Together they form a unique fingerprint.

Cite this