TY - JOUR
T1 - Deployment of acute mechanical circulatory support devices via the axillary artery
AU - Tayal, Raj
AU - Hirst, Colin S.
AU - Garg, Aakash
AU - Kapur, Navin K.
N1 - Publisher Copyright:
© 2019, © 2019 Informa UK Limited, trading as Taylor & Francis Group.
PY - 2019/5/4
Y1 - 2019/5/4
N2 - Introduction: Use of acute mechanical circulatory support (MCS) devices for high-risk cardiac intervention, cardiogenic shock, and advanced heart failure is growing. Alternate vascular access options for these devices remains a clinical challenge. Building on experience from trans-aortic valve replacement procedures, the axillary artery is becoming a common access route for acute MCS and represents an important advance in the development of acute MCS technologies. Areas covered: Authors review the clinical data and technical aspect of acute MCS deployment via the axillary artery. Axillary access is particularly useful for patients: 1) with severe peripheral vascular disease, 2) with hostile femoral access due to infection, indwelling endovascular devices, or obesity, and 3) to provide early mobility and ambulation. In this review, we discuss the deployment, technical issues and hemostasis regarding the use of intraaortic balloon pump, specifically, axillary intraaortic balloon pumps, trans-valvular left ventricular Impella pumps and arterial outflow of VA-ECMO. Expert opinion: Vascular comorbidities or device design may limit the traditional iliofemoral access route for acute mechanical circulatory support devices. Large bore access for the deployment of these devices through the axillary artery is feasible and safe when appropriate vascular access and closure techniques are used.
AB - Introduction: Use of acute mechanical circulatory support (MCS) devices for high-risk cardiac intervention, cardiogenic shock, and advanced heart failure is growing. Alternate vascular access options for these devices remains a clinical challenge. Building on experience from trans-aortic valve replacement procedures, the axillary artery is becoming a common access route for acute MCS and represents an important advance in the development of acute MCS technologies. Areas covered: Authors review the clinical data and technical aspect of acute MCS deployment via the axillary artery. Axillary access is particularly useful for patients: 1) with severe peripheral vascular disease, 2) with hostile femoral access due to infection, indwelling endovascular devices, or obesity, and 3) to provide early mobility and ambulation. In this review, we discuss the deployment, technical issues and hemostasis regarding the use of intraaortic balloon pump, specifically, axillary intraaortic balloon pumps, trans-valvular left ventricular Impella pumps and arterial outflow of VA-ECMO. Expert opinion: Vascular comorbidities or device design may limit the traditional iliofemoral access route for acute mechanical circulatory support devices. Large bore access for the deployment of these devices through the axillary artery is feasible and safe when appropriate vascular access and closure techniques are used.
KW - acute mechanical circulatory support devices
KW - Axillary artery
KW - impella
KW - intraaortic balloon pump
KW - percutaneous axillary artery access
KW - veno-arterial extracorporeal membrane oxygenation
UR - http://www.scopus.com/inward/record.url?scp=85064766242&partnerID=8YFLogxK
U2 - 10.1080/14779072.2019.1606712
DO - 10.1080/14779072.2019.1606712
M3 - Article
C2 - 31012351
AN - SCOPUS:85064766242
SN - 1477-9072
VL - 17
SP - 353
EP - 360
JO - Expert Review of Cardiovascular Therapy
JF - Expert Review of Cardiovascular Therapy
IS - 5
ER -